Electron probe microanalysis of minerals: Microanalyzer or scanning electron microscope?

Author:

Lavrent’ev Yu.G.1,Karmanov N.S.1,Usova L.V.1

Affiliation:

1. V.S. Sobolev Institute of Geology and Mineralogy, Siberian Branch of the Russian Academy of Sciences, pr. Akademika Koptyuga 3, Novosibirsk, 630090, Russia V.S. Sobolev Institute of Geology and Mineralogy, Siberian Branch of the Russian Academy of Sciences, pr. Akademika Koptyuga 3Novosibirsk 630090 Russia

Abstract

Abstract The results of electron probe microanalysis of several rock-forming minerals by wavelength-dispersive spectrometry (WDS) and energy-dispersive spectrometry (EDS) are compared, and the metrological characteristics of both methods are studied. The measurements were made with the use of a JXA-8100 (JEOL) microanalyzer with five wavelength-dispersive spectrometers and a MIRA 3 LMU (Tescan) scanning electron microscope equipped with an INCA Energy 450 XMax 80 (Oxford Instruments) microanalysis system. Specimens with olivine, garnet, pyroxene, ilmenite, and Cr-spinel grains were analyzed. The variation coefficients that characterize the repeatability of a single determination are found to be ~ 0.5% for WDS and ~ 0.9% for EDS in the compositional range of the main components (C > 10%). For minor components (1% < C < 10%), the variation coefficients are 1.4% and 3.0%, respectively, and for impurities (0.3% < C < 1%), 2.7% and 13%, respectively. For lower contents EDS is almost inapplicable. The ratio of the results obtained by the two methods is reproduced with high precision: For major components, the variation coefficient is 0.56%; for minor components, 1.7%; and even for impurities, it is ~ 8%. The magnitude of the bias is between 0.2 and 3.2 rel.%, which is acceptable. The results show that the accuracies of WDS and EDS are similar for measuring major and minor components of rock-forming minerals. Energy-dispersive spectrometry is inferior to wavelength-dispersive spectrometry for impurities and is completely inapplicable for still lower contents. This method is easier to implement, and the results are available soon after switching on the instrument. Wavelength-dispersive spectrometry needs more time for preparation, but it ensures a precise high-efficiency large-scale analysis of samples of similar compositions, even when the element contents are lower than 1%.

Publisher

GeoScienceWorld

Subject

Geology,Geophysics

Cited by 160 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3