Interobserver Variation of Colonic Polyp Measurement at Computed Tomography Colonography

Author:

Dulku Gurjeet1,Hewavitharana Chandra1,Halliday Tonya1,Ramsay Duncan1,Ho Richard1,Phillips Michael23,Mendelson Richard1

Affiliation:

1. Department of Diagnostic and Interventional Radiology, Royal Perth Hospital, Perth, Western Australia

2. Harry Perkins Institute for Medical Research, University of Western Australia, Perth, Western Australia

3. Centre for Medical Research, University of Western Australia, Perth, Western Australia

Abstract

Background The concept of “advanced polyps” is well accepted and is defined as polyps ≥10 mm and/or those having a villous component and/or demonstrating areas of dysplasia. Of these parameters, computed tomography colonography (CTC) can only document size. The accepted management of CTC-detected “advanced polyps” is to recommend excision if feasible, whereas the management of “intermediate” (6–9 mm) polyps is more controversial, and interval surveillance may be acceptable. Therefore, distinction between 6-9 mm and ≥10 mm is important. Methods Datasets containing 26 polyps originally reported as between 8-12 mm in diameter were reviewed independently by 4 CTC-accredited radiologists. Observers tabulated the largest measurement for each polyp on axial, coronal, sagittal, and endoluminal views at lung-window settings. These measurements were also compared to those determined by the computer-aided detection (CAD) software. Results The interobserver reliability intra-class correlation coefficient (ICC) for sagittal projection was 0.80 (“excellent” category of Hosmer and Lemeshow [2004]), 0.71 for axial (“acceptable”), 0.69 for coronal, and 0.41 for endoluminal (“unacceptable”). The largest of sagittal/axial/coronal measurement gave the best reliability with the smallest variance (ICC = 0.80; 95% CI 0.67–0.89). For 8 of 26 polyps, at least one radiologist's measurement placed the polyp in a different category compared to a colleague. For the majority of the polyps, the CAD significantly overestimated the readings compared to the largest of the manual measurements with an average difference of 1.6 mm ( P < .0001 for sagittal/axial/coronal). This resulted in 33% of polyps falling into a different category—10% were lower and 23% were higher ( P < .034). Conclusion It is apparent that around the cutoff point of 10 mm between “advanced” and “intermediate” polyps, interobserver performance is variable.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3