Author:
Rincón-Casado Alejandro,José Sánchez de la Flor Francisco
Abstract
This work presents a new parametric correlation for 2D enclosures with forced convection obtained from CFD simulation. The convective heat transfer coefficient of walls for enclosures depends on the geometry of the enclosure and the inlet and outlet openings, the velocity and the air to wall temperature difference. However, current correlations not dependent on the above parameters, especially the position of the inlet and outlet, or the temperature difference between the walls. In this work a new correlation of the average Nusselt number for each wall of the enclosure has been developed as a function of geometrical, hydrodynamic and thermal variables. These correlations have been obtained running a set of CFD simulations of a 3 m high sample enclosure with an inlet and outlet located at opposite walls. The varying parameters were: a) the aspect-ratio of the enclosure (L/H = 0.5 to 2), b) the size of the inlet and outlet (0.05 m to 2 m), c) the inlet and outlet relative height (0 m to 3 m high), and d) the Reynolds number (Rein = 103 to 105). Furthermore, a parametric analysis has been performed changing the temperature boundary conditions at the internal wall and founds a novel correlation function that relates different temperatures at each wall. A specifically developed numerical model based on the SIMPLER algorithm is used for the solution of the Navier–Stokes equations. The realisable turbulence k-ε model, and an enhanced wall-function treatment have been used. The heat transfer rate results obtained are expressed through dimensionless correlation-equations. All developed correlations have been compared with CFD simulations test cases obtaining a R2 = 0.98. This new correlation function could be used in building energy models to enhance accuracy of HVAC demands calculation and estimate the thermal load.
Reference24 articles.
1. Beausoleil-Morrison I., An algorithm for calculating convection coefficients for internal building surfaces for the case of mixed flow in rooms, Energy and Buildings 33 (2001) 351–361.
2. J. Clarke, Energy Simulation in Building Design, Butterworth-Heinemann, Oxford, 2001 (ISBN 0 7506 5082 6).
3. Beausoleil-Morrison Peeters L., I., A. Novoselac, Internal convective heat transfer modeling: Critical review and discussion of experimentally derived correlations, Energy and Buildings, Volume 43, Issue 9, September 2011, Pages 2227-2239, ISSN 0378-7788
4. J. Clarke, 1991, Internal convective heat transfer coefficients: a sensitivity study, Report to ETSU, Glasgow, UK.
5. Al-Sanea Sami A., M.F. Zedan, M.B. Al-Harbi, Effect of supply Reynolds number and room aspect ratio on flow and ceiling heat-transfer coefficient for mixing ventilation, International Journal of Thermal Sciences, Volume 54, April 2012, Pages 176-187, ISSN 1290-0729, 10.1016/j.ijthermalsci.2011.12.007.