Author:
Elsarrag Esam,Elsarraj Mohammad
Abstract
Prior to COVID-19, densely occupied areas were already suspected of making employees sick. Post-COVID-19, there is an urgent need to improve air quality and ventilation standards shall change. However, any changes to ventilation must consider other negative consequences including energy and health and well-being impacts from thermal discomfort and exposure to pollutants. The need for moving away from traditional energy sources and to find alternate energy sources is undoubtedly one of the primary objectives for a sustainable progress to humankind. The design and construction of buildings in hot-humid climates requires high energy consumption typically for air conditioning due to higher thermal loads. A further increase in ventilation rates will have intensive impact in energy consumption and infrastructure loads. This chapter presents the performance of an innovative fully integrated smart ventilation system with low energy consumption. It is all in one ventilating and air conditioning system that provides efficient, cost-effective, and sustainable cooled fresh air for open or enclosed spaces whilst achieving thermal comfort. Based on the application, it consists of multistages that can dehumidify and cool the air to the required comfort level. The system has shown 50–60% reduction in energy consumption compared with conventional systems.
Reference18 articles.
1. REHVA. COVID-19 Guidance Document. How to Operate HVAC and Other Building Service Systems to Prevent the Spread of the Coronavirus (SARS-CoV-2) Disease (COVID-19) in Workplaces. Belgium: Federation of European Heating, Ventilation and Air Conditioning Association; 2020. Available from: https://www.rehva.eu/fileadmin/user_upload/REHVA_COVID-19_guidance_document_V4_23112020.pdf
2. Fang Z, Lin Z, Mak C, Niu J, Tse K. Investigation into sensitivities of factors in outdoor thermal comfort indices. Building and Environment. 2018;128:129-142
3. Bonell M, Hufschmidt MM, Gladwell JS. Hydrology and Water Management in the Humid Tropics: Hydrological Research Issues and Strategies for Water Management. New York: Cambridge University Press; 2009. DOI: 10.1017/CBO9780511564468
4. Binarti F, Koerniawan M, Triyadi S, Utami S, Matzarakis A. A review of outdoor thermal comfort indices and neutral ranges for hot-humid regions. Urban Climate. 2020;31:100531
5. Elsarrag E, Alhorr Y. Modelling the thermal energy demand of a Passive-House in the Gulf Region. International Journal of Sustainable Built Environment. 2012;1:1-16