Evaluation of hemodynamic significance for paraprosthetic fistula after transcatheter aortic valve implantation

Author:

Ovcharenko E. A.1ORCID,Onishchenko P. S.1ORCID,Klyshnikov K. Yu.1ORCID,Ganyukov V. I.1ORCID,Shilov A. A.1ORCID,Vereshchagin I. E.1ORCID,Kokov A. N.1ORCID,Tarasov R. S.1ORCID,Barbarash L. S.1ORCID

Affiliation:

1. Research Institute for Complex Issues of Cardiovascular Diseases

Abstract

Highlights. Using ECHO and MSCT data, a numerical assessment of hemodynamic effects of paraprosthetic regurgitation following transcatheter aortic valve replacement was performed. A significant increase in the fluid flow, wall and viscous shear stresses in the area of regurgitation is shown. The modeling technique described in the paper can be used prospectively in assessing the optimal treatment modality in terms of predicting the quantitative characteristics of the flow, associated with the risks of destruction of red blood cells and thrombosisAim. To make a numerical assessment of hemodynamic effects of paraprosthetic regurgitation following transcatheter aortic valve replacement based on retrospective clinical data.Methods. The study included echocardiography and multi-slice computed tomography data as input data for modeling one pulsation of a fluid similar in properties to blood. Reconstruction of the paraprosthetic fistula and the ascending aorta was performed in the Mimics medium (Materialise, Belgium). The obtained 3D models were processed in the Salome software (OPEN CASCADE SAS, France), after which they were exported to HELYX-OS (ENGYS, Great Britain) to build a finite element mesh. The flows were modeled using the OpenFOAM software package version 6 (The OpenFOAM Foundation Ltd, UK).Results. The simulation result, expressed quantitatively and qualitatively in the form of diagrams of the measured parameters – fluid flow velocities, wall and viscous shear stresses, shows a significant increase in indicators in the area of paraprosthetic regurgitation. Thus, the velocity in the affected area was 1.9–4.2 m/s, which is 3.8 higher than the average value in the entire computational area. The wall shear stress value was up to 61 Pa in the critical area, which may indicate an increased risk of thrombus formation due to the initiation of the clotting cascade through the von Willebrand factor. The value of viscous shear stress, the main component of the destruction of red blood cells in laminar flow, amounted to 20–26 Pa, which, in general, is not enough for mechanical hemolysis.Conclusion. The modeling technique described in the paper can be used prospectively in assessing the optimal treatment modality in terms of predicting the quantitative characteristics of the flow, associated with the risks of destruction of red blood cells and thrombosis.

Publisher

NII KPSSZ

Subject

Cardiology and Cardiovascular Medicine,Critical Care and Intensive Care Medicine,Rehabilitation,Emergency Medicine,Surgery

Reference25 articles.

1. Rocatello G., El Faquir N., De Santis G., Iannaccone F., Bosmans J., De Backer O., Sondergaard L., Segers P., De Beule M., De Jaegere P., Mortier P. Patient-Specific Computer Simulation to Elucidate the Role of Contact Pressure in the Development of New Conduction Abnormalities After Catheter-Based Implantation of a Self-Expanding Aortic Valve. Circulation. Cardiovascular interventions. Circ Cardiovasc Interv; 2018; 11(2). doi:10.1161/CIRCINTERVENTIONS.117.005344

2. Perlman G.Y., Blanke P., Webb J.G. Transcatheter aortic valve implantation in bicuspid aortic valve stenosis. EuroIntervention. EuroPCR; 2016; 12: Y42–Y45. doi:10.4244/EIJV12SYA10

3. Thyregod H.G.H., Steinbrüchel D.A., Ihlemann N., Nissen H., Kjeldsen B.J., Petursson P., Chang Y., Franzen O.W., Engstrøm T., Clemmensen P., Hansen P.B., Andersen L.W., Olsen P.S., Søndergaard L. Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Valve Stenosis: 1-Year Results From the All-Comers NOTION Randomized Clinical Trial. Journal of the American College of Cardiology. J Am Coll Cardiol; 2015; 65(20): 2184–2194. doi:10.1016/J.JACC.2015.03.014

4. Mao W., Wang Q., Kodali S., Sun W. Numerical Parametric Study of Paravalvular Leak Following a Transcatheter Aortic Valve Deployment Into a Patient-Specific Aortic Root. Journal of biomechanical engineering. J Biomech Eng; 2018; 140(10). doi:10.1115/1.4040457

5. Bosmans B., Famaey N., Verhoelst E., Bosmans J., Vander Sloten J. A validated methodology for patient specific computational modeling of self-expandable transcatheter aortic valve implantation. Journal of biomechanics. J Biomech; 2016; 49(13): 2824–2830. doi:10.1016/J.JBIOMECH.2016.06.024