Determination of the Molecular Orientation of Poly(Propylene Terephthalate) Fibers Using Polarized Raman Spectroscopy: A Comparison of Methods

Author:

Frisk S.1,Ikeda R. M.1,Chase D. B.1,Rabolt J. F.1

Affiliation:

1. Dept. of Materials Science and Engineering, University of Delaware, Newark, Delaware 19711 (S.F., R.M.I., J.F.R.); and Central Research and Development, DuPont de Nemours, Wilmington, Delaware 19880 (D.B.C.)

Abstract

For the first time, four different methods to determine the degree of molecular orientation from polarized Raman spectroscopy measurements are compared. The great influence of molecular orientation on the properties of polymers has driven the development of multiple experimental techniques and procedures. This study is based on the C1–C4 ring stretching vibration of poly(propylene terephthalate) (PPT) at 1614 cm−1. It is shown that simply ratioing the band intensity obtained with the polarization parallel and perpendicular to the unique axis of the sample provides a good qualitative method to observe the evolution of orientation in a series of similar samples. To quantitatively compare the degree of orientation one needs to utilize a more complex method yielding the second- and fourth-order parameters of the orientation distribution function ( P2 and P4, respectively). To date, most studies have been based on the assumption of a cylindrically symmetric polarizibility tensor. It is shown that this assumption is highly questionable although this method has been used fairly successfully in the past. This method results in orientation parameters that are clearly different from those obtained with the two more complex procedures. The most complex method, both theoretically and experimentally, requires the most measurements per sample. Major problems have occurred when trying to calculate the desired parameters, in particular for samples with high birefringence. These problems are related to experimental complexities occurring for measurements when the samples are tilted with respect to the polarization direction of the incident light. These measurements are replaced by a simple determination of depolarization ratio in the third method. This method assumes that the depolarization ratio is independent of changes in molecular orientation and structure. It was found that this assumption is not correct. Thus, the most complex method is the method of choice to quantitatively determine the second- and fourth-order parameters of the orientation distribution function, unless one has knowledge of the depolarization ratio of each sample being studied. That knowledge permits the use of an experimentally simpler method to obtain the desired parameters.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Cited by 59 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3