Continuous Online Fourier Transform Infrared (FT-IR) Spectrometry Analysis of Hydrogen Chloride (HCl), Carbon Dioxide (CO2), and Water (H2O) in Nitrogen-Rich and Ethylene-Rich Streams

Author:

Stephenson Serena1,Pollard Maria1,Boit Kipchirchir1

Affiliation:

1. The Dow Chemical Company, Freeport, TX 77541 USA

Abstract

The prevalence of optical spectroscopy techniques being applied to the online analysis of continuous processes has increased in the past couple of decades. The ability to continuously “watch” changing stream compositions as operating conditions change has proven invaluable to pilot and world-scale manufacturing in the chemical and petrochemical industries. Presented here is an application requiring continuous monitoring of parts per million (ppm) by weight levels of hydrogen chloride (HCl), water (H2O), and carbon dioxide (CO2) in two gas-phase streams, one nitrogen-rich and one ethylene-rich. Because ethylene has strong mid-infrared (IR) absorption, building an IR method capable of quantifying HCl, H2O, and CO2 posed some challenges. A long-path (5.11m) Fourier transform infrared (FT-IR) spectrometer was used in the mid-infrared region between 1800 and 5000 cm−1, with a 1 cm−1 resolution and a 10 s spectral update time. Sample cell temperature and pressure were controlled and measured to minimize measurement variability. Models using a modified classical least squares method were developed and validated first in the laboratory and then using the process stream. Analytical models and process sampling conditions were adjusted to minimize interference of ethylene in the ethylene-rich stream. The predictive capabilities of the measurements were ±0.5 ppm for CO2 in either stream; ±1.1 and ±1.3 ppm for H2O in the nitrogen-rich and ethylene-rich streams, respectively; and ±1.0 and ±2.4 ppm for HCl in the nitrogen-rich and ethylene-rich streams, respectively. Continuous operation of the instrument in the process stream was demonstrated using an automated stream switching sample system set to 10 min intervals. Response time for all components of interest was sufficient to acquire representative stream composition data. This setup provides useful insight into the process for troubleshooting and optimizing plant operating conditions.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司