Determination of the Network Structure of Sensor Materials Prepared by Three Different Sol-Gel Routes Using Fourier Transform Infrared Spectroscopy (FT-IR)

Author:

Cappeletti Larissa B.1,Moncada Edwin2,Poisson Joel3,Butler Ian S.3,Santos João Henrique Z. Dos1

Affiliation:

1. Instituto de Química, UFRGS, Av. Bento Gonçalves, 9500, Porto Alegre, Brazil

2. Instituto Tecnológico Metropolitano, Robledo, Calle 73, #76A-354, Bloque F, Medellín, Colombia

3. Department of Chemistry, McGill University, 801 Sherbrooke Street, West, Montreal, Canada H3A 2K6

Abstract

Solid acid-base sensor materials were prepared by encapsulating three pH indicators (alizarin red, brilliant yellow, and acridine) within a silica matrix using a sol-gel approach through three different routes: (1) non-hydrolytic, (2) acid-catalyzed, and (3) base-catalyzed. Raman and Fourier transform infrared spectroscopies were used to evaluate the silica indicator interactions. Because vibrational bands assigned to functional groups present in the indicator molecules were not detected, the main silica stretching mode vSi-o between approximately 1300 and 1000 cm−1 was used to detect the presence of our indicators within the silica matrix. The large band centered at 1100 cm−1 was deconvoluted into four components corresponding to the longitudinal optic and transversal optic modes of the silicon monoxide (SiO)4 and (SiO)6 siloxane rings. Using the component area of each mode, it was possible to calculate the percentage of each structure. Such percentages ranged from 49% to 70% (SiO)6 for the analyzed samples, within a confidence level of 95% ( p = 0.05). (The confidence limits were 53–62%.) These results could be related to the pH indicator content, indicating that the quantity of the encapsulated molecule affects the (SiO)6 percentage values. In addition, a comparison with the radius of gyration obtained by small angle X-ray scattering was done. These results indicate that the analyte accesses the receptor elements through the passages between the siloxane rings but not through the siloxane rings themselves.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3