Flame Atomic Absorption Spectrometric Determination of Cadmium, Cobalt, and Nickel in Biological Samples Using a Flow Injection System with On-Line Preconcentration by Co-Precipitation without Filtration

Author:

Welz Bernhard1,Xu Shukun1,Sperling Michael1

Affiliation:

1. Department of Applied Research, Bodenseewerk Perkin-Elmer GmbH, D-7770 Überlingen, Germany

Abstract

Cadmium, cobalt, and nickel at ng/g to μg/g levels in plant and animal tissue reference materials and at μg/L levels in blood and urine were determined by flame atomic absorption spectrometry. The analyte elements were preconcentrated and separated from the bulk of the matrix by on-line co-precipitation with the hexamethylene ammonium hexamethylene dithiocarbamate iron(II) chelate complex in a flow injection system. The precipitate was collected in a knotted reactor made from 150-cm-long, 0.5-mm-i.d. Microline tubing without using a filter. The precipitate was dissolved in methyl isobutyl ketone and introduced directly into the nebulizer-burner system of an atomic absorption spectrometer. Ascorbic acid in an HC1/KC1 buffer was added on-line in order to reduce iron(III) to iron(II) because of its much better efficiency as a collector for trace elements. Reagent concentrations were optimized so that at least 200 mg/L of iron and 15 mg/L of copper could be tolerated in the sample solution without causing significant interferences. The portion of the analyte retained in the collector was about 70% for cadmium and 50% for cobalt and nickel. Enrichment factors of 24, 19, and 20 were obtained for cadmium, cobalt, and nickel, respectively, with the use of a 40-s co-precipitation time, resulting in enhancement factors, including the effect of the organic solvent, of 52, 43, and 52, respectively. The detection limits (3 σ) for cadmium, cobalt and nickel were 0.15, 1.3, and 1.5 μg/L, respectively, and the precision was 1.5% RSD for 10 μg/L Cd, 2.7% RSD for 50 μg/L Co, and 1.8% RSD for 50 μg/L Ni. The analytical results obtained for a number of standard reference materials and control samples were in good agreement with the certified or recommended values.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3