Affiliation:
1. Department of Chemical Engineering and Materials Science, Wayne State University, Detroit, Michigan 48202, U.S.A. (W.R., Y. G., E. W. R.); Max-Planck-Institut für Strömungsforschung, Bunsenstr. 10, 37073 Göttingen, Germany (W.R.); and LaVision 2D-Messtechnik, Gerhard-Gerdes-Str. 3, 37079 Göttingen, Germany (W.R., H.V.)
Abstract
Tunable excimer laser beams are increasingly used for imaging of combustion and/or flow systems. We (1) describe the need to use known polarization phenomena in interpreting diagnostics based on Rayleigh scattering (RS); (2) present relative RS cross sections for some important species at the most relevant wavelengths, 193 and 248 nm; and (3) measure the degree of linear polarization and the locking efficiency of the excimer beam, which are important diagnostic parameters that are otherwise difficult to obtain. Laser sheets, whose direction of linear polarization are adjustable, pass through gases. The Rayleigh light goes into intensified charge-coupled dervice (CCD) cameras. We report RS cross sections, normalized to those for N2, at 193 nm for H2, O2, H2O, CO2, and CH4, and at 248 nm for Ar, H2, O2, H2O, CO2, and CH4. Even when these normalized RS cross sections are used, the diagnostics can be very sensitive to the laser beam's polarization state. For example, for CO2, the normalized cross section changes by a factor of 4 with polarization. This usually unwanted sensitivity is greatest when an unmodified tunable excimer laser is used. The degree of polarization of the lasers, as well as their locking efficiency, is derived via RS from the spherical molecules Ar and CH4.
Subject
Spectroscopy,Instrumentation
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献