Infrared Intensities of Liquids XIII: Accurate Optical Constants and Molar Absorption Coefficients between 6500 and 435 cm−1 of Toluene at 25°C, from Spectra Recorded in Several Laboratories

Author:

Bertie John E.1,Jones R. Norman1,Apelblat Yoram1,Keefe C. Dale1

Affiliation:

1. Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2, Canada

Abstract

This paper presents accurate infrared absorption intensities of liquid toluene at 25°C. The accuracy is estimated from the agreement between the intensities measured by different spectroscopists using the same instrument in the same laboratory and also by different spectroscopists in different laboratories using instruments made by different manufacturers. The average agreement between integrated intensities over specific wavenumber ranges is about ±1.8%. The spectra from the different laboratories have been averaged, unweighted, to give intensity spectra of toluene that are presented as the best available. The use of data from different instruments in different laboratories has included the influence of systematic instrumental errors, so that the precision of the intensity data presented should be a better approximation to its accuracy than would be the case from an extensive study by one person on one instrument. The results obtained agree with the only measurements that have been made against a primary standard, the estimated accuracy of which is about 6%. The results are presented as graphs and tables of the molar absorption coefficient spectrum and the real and imaginary refractive index spectra between 6500 and 435 cm−1. The peak heights and the areas under the bands in the imaginary refractive index (i.e., absorption index) and molar absorption coefficient spectra are reported. The absorption index, k(ν˜), and molar absorption coefficient, Em (ν˜), values are believed to be accurate to an average ±2.5% at the peaks of 39 strong, medium, and weak bands and ±1.9% at the peaks of 51 very weak bands below 4100 cm−1. Above 4100 cm−1, 11 very weak bands have an average accuracy of ±1.3%. The baseline k(ν˜) values are accurate to between ±3 and ±10%. The areas under bands or band groups in k(ν˜) and εm (ν˜) spectra are accurate to 2.4% on average, or 1.2% for strong, medium, and weak band groups between 3150 and 775 cm−1 with 0.002 < kmax < 0.112. The real refractive index, n(ν˜), values are believed to be accurate to 0.2%.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Cited by 55 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3