Evaluation of the Ability of Physical Therapists to Palpate Intrapelvic Motion With the Stork Test on the Support Side

Author:

Hungerford Barbara A1,Gilleard Wendy2,Moran Michael3,Emmerson Cathryn4

Affiliation:

1. BA Hungerford, PhD, BAppSci (Physio), is Consultant Physiotherapist, Department of Physiotherapy, Sydney Spine and Pelvis Centre, Drummoyne, New South Wales, Australia

2. W Gilleard, PhD, MSc(Hons), is Senior Lecturer, School of Exercise Science and Sport Management, Southern Cross University, Lismore, New South Wales, Australia

3. M Moran, MHlthSc(Sports Physio), BAppSc(Physio)Hons, is Principal Physiotherapist, Carlingford Physiotherapy Centre, Carlingford, New South Wales, Australia

4. C Emmerson, MHlthSc(Sports Physio), BAppSc(Physio), is Principal Physiotherapist, Stanmore Physiotherapy and Sports Clinic, Stanmore, New South Wales, Australia

Abstract

Background and Purpose Clinical indicators of pelvic girdle dysfunction are limited. However, research has shown that the pattern of intrapelvic motion is altered during single-leg support in subjects with pelvic girdle pain (PGP). Functionally, no relative motion should occur within the pelvis during load transfer, whereas anterior rotation of the innominate bone relative to the sacrum occurs during weight bearing in the presence of PGP. The aim of this study was to investigate whether the pattern of intrapelvic motion could be detected reliably during a new clinical assessment test for functional load transfer: the Stork Test on the support side. Subjects and Methods Three physical therapists were randomly assigned to palpate the motion of the innominate bones and sacrum in 33 subjects during the Stork Test on the support side. The direction of bone motion was indicated on 2-point and 3-point scales. Results When a 2-point scale was used, intertherapist agreement on the pattern of intrapelvic motion occurring during load transfer showed good reliability (left κ=.67, right κ=.77), and the percentage of agreement was high (left=91.9%, right=89.9%). A 3-point scale resulted in moderate reliability for both the left and the right sides (left κ=.59, right κ=.59), and the percentage of agreement decreased to 82.8% (left) and 79.8% (right). Discussion and Conclusion The ability of the physical therapists to reliably palpate and recognize an altered pattern of intrapelvic motion during the Stork Test on the support side was substantiated. The ability to distinguish between no relative movement and anterior rotation of the innominate bone during a load-bearing task was good. Further research is needed to determine the validity of this test for detecting pelvic girdle dysfunction.

Publisher

Oxford University Press (OUP)

Subject

Physical Therapy, Sports Therapy and Rehabilitation

Reference20 articles.

1. Sacroiliac joint referral patterns upon application of a new injection/arthrography technique, I: asymptomatic volunteers;Fortin;Spine,1994

2. The sacroiliac joint in chronic low back pain;Schwarzer;Spine,1995

3. Clinical tests of the sacroiliac joint: a systematic methodological review, part 1: reliability;van der Wurff;Man Ther,2000

4. Inter- and inter-examiner reliability of palpation for sacroiliac joint dysfunction;Carmichael;J Manipulative Physiol Ther,1987

5. Intra-examiner and inter-examiner reliability of the Gillet test;Meijne;J Manipulative Physiol Ther,1999

Cited by 65 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3