Test-Retest Reliability and Minimal Detectable Change on Balance and Ambulation Tests, the 36-Item Short-Form Health Survey, and the Unified Parkinson Disease Rating Scale in People With Parkinsonism

Author:

Steffen Teresa1,Seney Megan2

Affiliation:

1. T Steffen, PT, PhD, is Professor, Program in Physical Therapy, Concordia University Wisconsin, Mequon, Wis. Dr Steffen's mailing address is: N102 W7525 St James Ct, Cedarburg, WI 53102 (USA)

2. M Seney is a student in the Program in Physical Therapy, Concordia University Wisconsin

Abstract

Background and PurposeDistinguishing between a clinically significant change and change due to measurement error can be difficult. The purpose of this study was to determine test-retest reliability and minimal detectable change for the Berg Balance Scale (BBS), forward and backward functional reach, the Romberg Test and the Sharpened Romberg Test (SRT) with eyes open and closed, the Activities-specific Balance Confidence (ABC) Scale, the Six-Minute Walk Test (6MWT), comfortable and fast gait speed, the Timed “Up & Go” Test (TUG), the Medical Outcomes Study 36-Item Short-Form Health Survey (SF-36), and the Unified Parkinson Disease Rating Scale (UPDRS) in people with parkinsonism.SubjectsThirty-seven community-dwelling adults with parkinsonism (mean age=71 years) participated. The Hoehn and Yahr Scale median score of 2 was on the lower end of the scale; however, the scores ranged from 1 to 4.MethodsSubjects were tested twice by the same raters, with 1 week between tests. Test-retest reliability was calculated using intraclass correlation coefficients (ICCs). Minimal detectable change was calculated using a 95% confidence interval (MDC95).ResultsThe ICCs for test-retest reliability were above .90 for the BBS, ABC Scale, SRT with eyes closed, 6MWT, and comfortable and fast gait speeds. The MDC95 values for those functional tests were: BBS=5/56, ABC Scale=13%, SRT with eyes closed=19 seconds, 6MWT=82 m, comfortable gait speed=0.18 m/s, and fast gait speed=0.25 m/s. The ICCs for test-retest reliability of SF-36 scores were above .80, with the exception of the social functioning subscale. The MDC95 values for the SF-36 ranged between 19% and 45%. The MDC95 values for the UPDRS Activities of Daily Living section, Motor Examination section, and total scores were 4/52, 11/108, and 13/176, respectively.Discussion and ConclusionMinimal detectable change values are useful to therapists in rehabilitation and wellness programs in determining whether change during or after intervention is clinically significant. High test-retest reliability of scores for the BBS, ABC Scale, SRT with eyes closed, 6MWT, and gait speed make them trustworthy functional assessments in people with parkinsonism. The SF-36 and UPDRS provide quality-of-life and disease severity rating values in the ongoing assessment of people with parkinsonism.

Publisher

Oxford University Press (OUP)

Subject

Physical Therapy, Sports Therapy and Rehabilitation

Reference93 articles.

1. Establishing minimal clinically important differences for scores on the Pediatric Evaluation of Disability Inventory for inpatient rehabilitation;Iyer;Phys Ther,2003

2. Defining the minimum level of detectable change for the Roland-Morris Questionnaire;Stratford;Phys Ther,1996

3. Interpreting change scores of tests and measures used in physical therapy;Haley;Phys Ther,2006

4. Differential responses to measures of gait performance among healthy and neurologically impaired individuals;Teixeira da Cunha-Filho;Arch Phys Med Rehabil,2003

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3