Clinical evaluation of one-step impression technique and definitive casts

Author:

Özcan Işıl,Köroğlu Aslıhan,Kale Ediz,Özçelik Tuncer,Yilmaz Burak

Abstract

Background/Aim: The purpose of this study was to evaluate the quality of impressions made with vinyl polysiloxane (VPS) material in clinical conditions by using the one-step impression technique, and the quality of casts generated from these impressions. The effect of operator, number and location of abutments, and presence of bleeding were also investigated. Material and Methods: A total of 150 fixed dental prosthesis (FDP) impressions were taken and considered acceptable by 3 experienced prosthodontists in a clinic in an institutional setting. The impressions were evaluated and rated by another experienced prosthodontist and respective casts were evaluated and rated by an experienced dental technician using a digital microscope with ×200 magnification. The defects observed were noted as bubbles, voids, tears, or other defects. A scale was structured for the impressions and casts with ratings of Alpha (excellent; no defects), Bravo (acceptable; small defects), Charlie (inadequate; defects that require remaking of impression), and Delta (unacceptable; substantial defects at preparation finish lines). The data were analyzed with the Chi-square test for inter-operator, number of abutments, and location of prepared tooth variables (a=0.05). Results: The scale ratings were 85 Alpha (57%), 52 Bravo (34%), 6 Charlie (4%), and 7 Delta (5%) for the impressions, and 81 Alpha (54%), 58 Bravo (39%), 4 Charlie (3%), and 7 Delta (5%) for the respective casts. Sixty-nine percent of the impressions and respective casts were rated with the same score. The scale rating results were not influenced by inter-operator variability or number of abutments. Location of the prepared tooth was significant for anterior/posterior (p=0.04), but was not significant for maxilla/ mandible (p>0.05). Bleeding at the preparation site had a significant effect on the acceptability of the impression (p=0.003). Conclusions: The acceptability of VPS impressions using onestep technique was independent of the operator, number of abutments, or whether the prepared tooth was in maxilla or mandible. Impressions of teeth in the anterior region were more acceptable than those located in the posterior. Bleeding negatively affected the acceptability of the impressions. Clinicians may use VPS impressions for the fabrication of FDPs using onestep dual-phase technique. However, clinicians should carefully evaluate their impressions when bleeding is present when using this technique.

Publisher

Centre for Evaluation in Education and Science (CEON/CEES)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3