Ultrafast ultrasound localization microscopy method for spinal cord mircovasculature imaging

Author:

Yu Jun-Jin,Guo Xing-Yi,Sui Yi-Hui,Song Jian-Ping,Ta De-An,Mei Yong-Feng,Xu Kai-Liang, , , ,

Abstract

Function of spinal cord is crucial to nerve conduction pathway. Traumatic spinal cord injury often results in a vasculature disruption after primary insult and further leads to abnormal responses of the intact vessels in neighboring tissue during secondary injury. Therefore, the vasculature and blood supply play significant roles in evaluating the spinal cord function . Ultrasound localization microscopy (ULM) overcomes the shortcomings of extensively used angiography, such as computed tomography angiography (CTA) and magnetic resonance angiography (MRA), in terms of limited resolution, radiation and poor-portability, which meets the needs of comprehensive intraoperative examination and prognosis tracking. In this study, an L22-14vX probe with a transmission frequency of 15.625 MHz is utilized, yielding an imaging wavelength of 100 μm. The ULM is conducted based on ultrafast ultrasound technology with multiple tilted plane-wave illuminations. Robust principal component analysis (RPCA) based spatial-temporal clutter filtering method is used for separating the microbubble signals from tissue signals and high frequency noise. Through microbubble localization, trajectory tracking and mapping, subwavelength super-resolution ultrasound imaging is finally achieved. The whole process of microbubble localization and vessel reconstruction are monitored through measuring the time dependent microbubble detections and saturation. Saturation curve corresponds to the time dependent total area covered by microbubble detections on the image. Quantification analysis is carried out for evaluating the imaging results including resolution measurements based on the Fourier ring correlation (FRC) and full-width at half-maximum (FWHM). The <i>i</i><i>n-vivo</i> experimental results show that ULM can be used to obtain super-resolution vasculature imaging in rat spinal cord. The velocity distributed from 1 mm/s to 50 mm/s can be detected. Within the same vessel, the velocity of a point is inversely correlated with the distance from the point to the center of the vessel. The velocity in the center of the vessel is larger than that at the wall of the vessel. The larger vessels support higher flow in the center of the vessel. The FWHM results indicate that ultrafast Doppler displays vessels in diameters between 135 μm and 270 μm while ULM displays them in diameters between 28 μm and 35 μm. The FRC-based resolution evaluation shows that the ULM achieves a super resolution of 16 μm, much less than the imaging wavelength of 100 μm. Yet, long acquisition time is required to detect microbubbles in the smallest vessels, leading to long reconstruction of the microvasculature, which is still a problem worth studying . Compromise between saturation and acquisition time needs considering. Generally speaking, microbubbles are more likely to flow in large vessels, leading to relatively short reconstruction time of large vessels. When saturation curve almost converges, the imaging improvement with new vessels is not so significant that the detail sacrifice of some small microvessels can reduce acquisition time (i.e. most of microvasculature can still be gained when the saturation curve does not converge). Besides, the increase of microbubble concentration and advanced track identification and extraction may also accelerate the saturation rate of convergence with acquisition time decreasing. In conclusion, ULM can be used to obtain a super-resolution imaging of spinal cord microvasculature, giving a 10-fold improvement in resolution in comparison with ultrafast Doppler imaging. Relevant results can facilitate the super-resolution ULM imaging of spinal cord which may promote the function diagnosis, treatment intervention, disability prevention, and prognosis recovery of spinal cord injury.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3