Author:
Sha Jin ,Xu Jian-Ping ,Xu Li-Jun ,Zhong Shu ,
Abstract
Pulse train (PT) control technique is a discrete, nonlinear control technique for switching converter which benefits from simple design and ultra fast transient response. As an output-power-control-based control technique, a low-frequency oscillation phenomenon occurs in voltage-mode PT controlled switching converter operating in continuous conduction mode. This phenomenon will seriously affect the steady and transient performances of switching converter. In this paper, a current-mode PT (CM-PT) controlled switching converter is studied. The normally working region is studied and the parameter conditions are estimated. Targeting the problem of CM-PT control technique, a modified control technique is proposed.
Publisher
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Subject
General Physics and Astronomy
Reference12 articles.
1. Qin M, Xu J P, Zhou G H, Mu Q B 2009 Proc. IEEE 4th ICIEA Xi'an, China, May 25-27, 2009 p2924
2. Sha J, Bao B C, Xu J P, Gao Y 2012 Acta Phys. Sin. 61 120501 (in Chinese) [沙金, 包伯成, 许建平, 高玉 2012 物理学报 61 120501]
3. Ferdowsi M, Emadi A, Telefus M, Shteynberq A 2005 IEEE Trans. Power Electron. 20 798
4. Sha J, Xu J P, Bao B C, Yan T S 2014 IEEE Trans. Ind. Electron. 61 1562
5. Telefus M, Shteynberg A, Ferdowsi M, Emadi A 2004 IEEE Trans. Power Electron. 19 757
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献