Experimental research on a 50 mK multi-stage adiabatic demagnetization refrigerator

Author:

Li Ke,Wang Ya-Nan,Liu Ping,Yu Fang-Qiu,Dai Wei,Shen Jun, ,

Abstract

<sec>With the development of condensed matter physics, space observation, and quantum technology in recent years, the demand for ultra-low temperature refrigeration has increased. The adiabatic demagnetization refrigerator (ADR) has the advantages of being unaffected by gravity, compact structure, and relatively low cost, which can meet the needs of space and ground applications.</sec><sec>In this paper, a 50 mK multi-stage ADR is designed and developed which comprises a GM-type pulse tube cryocooler for precooling and three ADR stages connected in series. For easy installation and maintenance, the three ADR stages are placed on a separate cold plate which is connected to the 4 K cold plate via copper columns. The Dy<sub>3</sub>Ga<sub>5</sub>O<sub>12</sub> (GGG) is employed as the refrigerant in the first stage, whereas CrK(SO<sub>4</sub>)<sub>2</sub> · 12H<sub>2</sub>O (CPA) is utilized for the second stage and third stage. To control heat transfer between stages and the 4 K heat sink, active gas-gap heat switch and passive gas-gap heat switch are developed, with the latter having a switching ratio over 1000.</sec><sec>The 4 T, 2 T and 1 T superconducting magnets are utilized in the 1st, 2nd and 3rd stage, respectively, and a numerical model is used to optimize the design of magnetic shielding. In addition, an ADR simulation model with a proportional-integral-derivative (PID) controller is constructed to assist in tuning the controller parameters in the experiment. The lowest temperature achieved in the experiment is 38 mK, with a temperature fluctuation of 10.6 μK. The durations of different cooling power (1, 2 and 3 μW) at 100 mK are also measured. It is calculated that the no-load maintenance time is about 4.3 h, the leakage heat power is about 4.5 μW, and the total cooling capacity is about 71 mJ. This refrigerator is the first Chinese multi-stage ADR that can reach a temperature under 50 mK, which lays an important foundation for subsequent research on continuous adiabatic demagnetization refrigeration.</sec>

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3