Author:
Li Xiao-Li ,Sun Jian-Gang ,Tao Ning ,Zeng Zhi ,Zhao Yue-Jin ,Shen Jing-Ling ,Zhang Cun-Lin , , , ,
Abstract
In order to measure diffusivity of carbon/carbon composite,a nonlinear fitting method for data processing of transmission pulsed infrared thermography is proposed.It is a kind of method of comparing the experimental data with the theoretical values under a fitting parameter and obtaining the optimal result by an iteration method.Traditional half rise time method calculates the diffusivity through searching the half maximum temperature rise time,which is very difficult when a long capture time is required or a big temperature rise is needed.Unlike the traditional half rise time method,the nonlinear data fitting method can effectively eliminate the capture time restriction and weaken the badsignal-to-noise ratio effects.Before applying this method to carbon/carbon composite examination,a common stainless steel 304 specimen that has reliable diffusivity indicated in the literature,is employed to evaluate the measurement accuracy and confirm the effect of fitting length on the fitting results.The examination results illustrate that the measurement accuracy of stainless steel 304 is as high as 0.3%,and the influence is very small if the fitting data length keeps no less than 1/5 that of half rise time method (t1/2).Specifically,the fitting result changes less than 1% when the fitting length varies from 1 to 4 times of t1/2.With this evaluation result,the nonlinear fitting method is further applied to testing 6 carbon/carbon composite specimens from both sides of each specimen.Furthermore,the diffusivity differences among the specimens and the uniformities of the materials are analyzed through the thermal diffusivity results gained from the examination.The results demonstrate that average diffusivity values of both sides are similar,but the diffusivities among the specimens are different greatly.Of the diffusivities of specimens,the diffusivity value 5.125 is the smallest,while the diffusivity value 6.915 is the biggest.The gap between them is nearly 30% of their mean value. Some nonuniformity areas are also examined from the diffusivity images of carbon/carbon composite samples.So we can obtain not only diffusivity values but also uniformity information of the carbon/carbon composite from this nonlinear fitting transmission thermography examination.
Publisher
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Subject
General Physics and Astronomy
Reference23 articles.
1. Windhorst T, Blount G 1997 Mater. Design 18 11
2. Li H J, Luo R Y, Yang Z 1997 J. Mater. Eng. 8 8(in Chinese)[李贺军, 罗瑞盈, 杨峥1997材料工程 8 8]
3. ASTM E1225-042004 Standard Test Method for Thermal Conductivity of Solids by Means of the Guarded-Comparative-Longitudinal Heat Flow Technique (West Conshohocken:ASTM International) pp1-8
4. Tan J C, Tsipas S A, Golosnoy I O, Curran J A, Paul S, Clyne T W 2006 Surf. Coat. Technol. 201 1414
5. Lipaev A A 2012 Meas. Tech. 54 1264
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献