Evaluation of Elasticity, Dose Reduction, and Image Quality on Sr-Pb Shield for Thoracic CT Examination

Author:

Nurul Hidayatullah 1,Heri Sutanto 1,Choirul Anam 2,Yosi W. Wardhana 1,Riska Amilia 1,Ariij Naufal 1,Ulil A. Taufiq

Affiliation:

1. Department of Physics, Faculty of Science and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia

2. Installation of Radiology, Rumah Sakit Telogorejo Semarang, Jl. Kh Ahmad Dahlan, Karang Kidul, Semarang Tengah, Kota Semarang, Jawa Tengah 50134, Central Java, Indonesia

Abstract

The performance of chest CT always involved the scanning of breast since it was positioned within the scan range. It makes this organ always receives an amount of radiation that potentially harms the biological system. Many attempts have been performed to reduce the radiation doses objected to breast, including the utilization of radio-protective shield. This study aims to develop the radio-protector shield silicon rubber (SR) - Lead (Pb) based for the breast. The shield was developed with a thickness of 0.6 mm and SR:Pb ratios of 100:0, 98:2, 96:4, 94:6, and 92:8. After that, the shield was placed over an anthropomorphic phantom. The shield’s reliability was tested in terms of elasticity, radiation dose, and image quality. The elasticity level of a material was indicated by Young's modulus yielded. Our results showed that the Young's modulus decreased as the percentage of Pb increased. Breast surface dose was measured using a Radcal ion chamber on the surface of the breast phantom. The measured dose was reduced as Pb increased, the dose using shielding at the highest percentage of 92:8 wt% is 8.71 mGy. The measured SNR without using shielding is 18.38, while the measured SNR using shielding 100:0, 98:2, 96:4, 94:6 and 92:8 was 18.47; 17.45; 16.65; 15.49, and 14.23, respectively. SR-Pb shielding has a Young’s modulus less than 0.035 GPa and can cover the chest of phantom well. SR-Pb shield was able to reduce the breast dose by 26% while the image quality in all variations of the SR:Pb ratio was above the rose criterion value with an insignificant decrease.

Publisher

Technoscience Academy

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3