ALGORITHM FOR APPLICATION OF METHODS FOR DETECTING CENTRAL SIGNS OF AN EMERGENCY SITUATION DUE TO FIRE AT CRITICAL INFRASTRUCTURE FACILITIES

Author:

Shcherbak O.1ORCID,Neshpor O.2ORCID,Derevyanko O.1ORCID,Yeremenko S.2ORCID,Shevchenko R.1ORCID

Affiliation:

1. National University of Civil Defense of Ukraine

2. Institute of Public Administration and Scientific Research on Civil Protection

Abstract

The work is devoted to the solution of an actual scientific task in the field of civil protection, namely, the development of an algorithm for the application of the technique of detecting focal signs of an emergency situation due to a fire at critical infrastructure facilities. Recommendations for the practical application of the methodology as the basis of the method of non-destructive control of the processes of preventing emergency situations due to a fire of a terrorist nature at the objects of critical infrastructure of Ukraine are given. the algorithm for the application of the method of detecting focal signs of an emergency situation due to a fire at critical infrastructure facilities consists of three procedures, namely: procedures for conducting measurements at a critical infrastructure facility, procedures for statistical processing of measurement results, fire reconstruction procedures. The received general recommendations of the fire reconstruction procedure can be reduced to the following. In particular, we note that the value of the electrical resistance of soot is related to the mode of combustion in one or another zone. If this value, which was measured directly above the investigated area, exceeds 10101011 Ohm, then this indicates that there was no intense flame burning in this area, but the burning took place in the form of smoldering. Long-term smoldering of a fire load in conditions of insufficient air exchange can lead to the formation of a thick layer of greasy soot on the ceiling and in the upper part of the walls, sometimes with clear drops of the liquid phase or drop-like spots. This can be observed in small rooms and other volumes that are not ventilated. If the combustion moves from such premises to a larger space with better air exchange, and a flaming combustion occurs, then the formed electrical resistance pattern will mainly reflect the development of flaming combustion. The source of the fire may appear in the form of soot burning or extremely low values of its electrical resistance, or vice versa, in a rather thick layer of soot with a high content of extractive substances. Thus, the interpretation of the results of the measurement of electrical resistance must be accompanied by an analysis of the specifics of the volume-planning decisions of the building (room), the conditions of air exchange, and the distribution of the fire load. The obtained results of the soot research can be used within the framework of fire engineering expertise to reconstruct the process of the occurrence and development of combustion, including to establish the center of the fire. Keywords: emergency situation, critical infrastructure object, technique, focal signs, thermal damage.

Publisher

O.M.Beketov National University of Urban Economy in Kharkiv

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3