Author:
,Afanaciev K.,Baldini A. M.,Ban S.,Baranov V.,Benmansour H.,Biasotti M.,Boca G.,Cattaneo P. W.,Cavoto G.,Cei F.,Chiappini M.,Chiarello G.,Corvaglia A.,Cuna F.,Maso G. Dal,De Bari A.,De Gerone M.,Barusso L. Ferrari,Francesconi M.,Galli L.,Gallucci G.,Gatti F.,Gerritzen L.,Grancagnolo F.,Grandoni E. G.,Grassi M.,Grigoriev D. N.,Hildebrandt M.,Ieki K.,Ignatov F.,Ikeda F.,Iwamoto T.,Karpov S.,Kettle P.-R.,Khomutov N.,Kobayashi S.,Kolesnikov A.,Kravchuk N.,Krylov V.,Kuchinskiy N.,Kyle W.,Libeiro T.,Malyshev V.,Matsushita A.,Meucci M.,Mihara S.,Molzon W.,Mori Toshinori,Morsani F.,Nakao M.,Nicolò D.,Nishiguchi H.,Ochi A.,Ogawa S.,Onda R.,Ootani W.,Oya A.,Palo D.,Panareo M.,Papa A.,Pettinacci V.,Popov A.,Raffaelli F.,Renga F.,Ritt S.,Rossella M.,Rozhdestvensky A.,Schwendimann P.,Shimada K.,Signorelli G.,Stoykov A.,Takahashi M.,Tassielli G. F.,Toyoda K.,Uchiyama Y.,Usami M.,Venturini A.,Vitali B.,Voena C.,Yamamoto K.,Yanai K.,Yonemoto T.,Yoshida K.,Yudin Yu. V.
Abstract
AbstractThe MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the $$\upmu ^+ \rightarrow {\textrm{e}}^+ \upgamma $$
μ
+
→
e
+
γ
decay down to $$\sim 6 \times 10^{-14}$$
∼
6
×
10
-
14
almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.
Publisher
Springer Science and Business Media LLC
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. The latest performance and refurbishment of the pixelated Timing Counter (pTC) in the MEG II experiment;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;2024-11
2. Alignment of the MEG II cylindrical drift chamber;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;2024-10
3. A liquid hydrogen target for the calibration of the MEG-II LXe calorimeter;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;2024-09
4. Heavy Neutral Lepton Search and μ → eγ Constraints in Case of Type-I Seesaw;Symmetry;2024-07-04
5. Performances of a new generation tracking detector: the MEG II cylindrical drift chamber;The European Physical Journal C;2024-05-07