Multicentre investigation of neutron contamination at cardiac implantable electronic device (CIED) location due to high-energy photon beams using passive detectors and Monte Carlo simulations

Author:

Mele A.,Aslian H.,Bolzonella M.ORCID,Caresana M.,Ciolini R.,d’Errico F.,Longo F.,Mordacchini C.,Quattrocchi M.,Kaiser S. Ren,Nascimento D. Siqueira,Severgnini M.,Tuttoilmondo E.

Abstract

AbstractRadiotherapy treatments involving LINACs operating at accelerating potentials >10 MV generate (photo)neutrons which deliver dose to patients also outside the target volume. This effect is particularly relevant for patients with cardiac implantable electronic devices (CIEDs), which can be damaged by the therapeutic irradiation. In the last few years, there has been a rising interest in this issue, and it seems that damage to CIEDs is primarily associated with the thermal component of the photoneutron field. In particular, a recent study led by Politecnico di Milano considered CIEDs from various manufacturers and showed that some of these devices can be damaged after an irradiation with a thermal neutron fluence of about $$10^{9}\hbox { cm}^{-2}$$ 10 9 cm - 2 . The present work results from a collaboration among Politecnico di Milano, the University of Pisa, the University of Trieste and three Italian hospitals located in Lucca, Trieste and Varese, respectively, and it is primarily aimed at evaluating the thermal neutron fluence in CIED region for some high-energy treatments delivered at 15 and 18 MV and to determine whether it is comparable to the critical value given above, which has been experimentally determined to be potentially harmful for CIEDs. Thermal neutron fluence was measured through CR-39 detectors and TLDs, which were housed inside a BOMAB-like phantom mimicking the patient’s trunk. The experimental sessions involved two models of LINAC, Varian Clinac DHX (Varese hospital) and Elekta Synergy (Lucca and Trieste hospitals). The experimental results show that the treatments considered in this study can lead to a thermal neutron fluence in the cardiac region comparable to the critical value. Furthermore, detailed Monte Carlo geometries for the facilities involved in this project were developed with the MCNP code (v. 6.2), and they were tested by comparing simulation results to measurements considering some benchmark irradiation plans. Bubble detectors were also employed for fast neutron fluence measurements to be compared to simulation outputs. These computational models stand out as promising tools for the investigations required in this work, and they can be used for further studies also extending their use to analogous facilities hosting the same models of LINACs.

Publisher

Springer Science and Business Media LLC

Subject

General Physics and Astronomy,Fluid Flow and Transfer Processes

Reference30 articles.

1. M. Miften, D. Mihailidis, S.F. Kry, C. Reft, C. Esquivel, J. Farr, D. Followill, C. Hurkmans, A. Liu, O. Gayou, M. Gossman, M. Mahesh, R. Popple, J. Prisciandaro, J. Wilkinson, Management of radiotherapy patients with implanted cardiac pacemakers and defibrillators: A report of the AAPM TG-203$$^\dagger $$. Med. Phys. 46(12), 757–788 (2019). https://doi.org/10.1002/mp.13838

2. 2017 HRS Expert Consensus Statement on Cardiovascular Implantable Electronic Device Lead Management and Extraction—Heart Rhythm Society. Accessed 27 Feb 2023. https://www.hrsonline.org/guidance/clinical-resources/2017-hrs-expert-consensus-statement-cardiovascular-implantable-electronic-device-lead-management

3. B. Gauter-Fleckenstein, C. Barthel, S. Büttner, F. Wenz, M. Borggrefe, E. Tülümen, Effectivity and applicability of the German DEGRO/DGK-guideline for radiotherapy in CIED-bearing patients. Radiother. Oncol. 152, 208–215 (2020). https://doi.org/10.1016/j.radonc.2020.01.006

4. M. Zecchin et al., Management of patients with cardiac implantable electronic devices (CIED) undergoing radiotherapy: a consensus document from Associazione Italiana Aritmologia e Cardiostimolazione (AIAC), Associazione Italiana Radioterapia Oncologica (AIRO), Associazione Italiana Fisica Medica (AIFM). Int. J. Cardiol. 255, 175–183 (2018). https://doi.org/10.1016/J.IJCARD.2017.12.061

5. A. Naseri, A. Mesbahi, A review on photoneutrons characteristics in radiation therapy with high-energy photon beams. Rep. Pract. Oncol. Radiother. 15, 138–144 (2010). https://doi.org/10.1016/j.rpor.2010.08.003

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3