Author:
Adorna Marcel,Brodner Stefan,Falta Jan,Zlámal Petr,Fíla Tomáš
Abstract
Three different tools for Digital Image Correlation (DIC) were used for evaluation of dynamic experiments performed using custom Open Hopkinson Pressure Bar (OHPB) apparatus. High strain-rate measurements were performed on specimens of advanced cellular materials with predefined structure and negative Poisson’s ratio. Low impedance polymethyl methacrylate (PMMA) bars instrumented with foil strain-gauges were used for dynamic loading of the specimens. Experiments were observed using a pair of high-speed cameras for imaging of loading process in sufficient quality. Custom developed evaluation DIC tool implemented in Matlab, open-source Matlab tool (NCorr) and commercial DIC software (ISTRA 4D) were all used for evaluation of image sequences recorded by high-speed cameras. Comparison of results obtained using all three different DIC tools and results of complementary strain-gauge measurement are shown in this paper. Verification of reliability of custom made DIC software tool is presented.
Publisher
Czech Technical University in Prague - Central Library
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献