Validation method for determining enrofloxacin and tylosin levels in broiler liver, kidney, and muscle using high-performance liquid chromatography

Author:

Wijayanti Agustina Dwi1ORCID,Ardiansyah Rahmad Dwi1ORCID,Pratama Anggi Muhtar1ORCID,Haryanto Aris2ORCID,Fitriana Ida1ORCID

Affiliation:

1. Department of Pharmacology, Faculty of Veterinary Medicine, Universitas Gadjah Mada, Jl. Fauna no. 2 Karangmalang, Yogyakarta, Indonesia.

2. Department of Biochemistry, Faculty of Veterinary Medicine, Universitas Gadjah Mada, Jl. Fauna no. 2 Karangmalang, Yogyakarta, Indonesia.

Abstract

Background and Aim: Enrofloxacin and tylosin can be combined into an antibiotic formulation which is expected to have a broader range of antibacterial activity against various infections in broilers. Validation method analysis of the levels of these two active compounds needs to be done for future use in pharmacokinetic or residual studies. The present study aims to determine a suitable validation method of isocratic high-performance liquid chromatography (HPLC) to measure the concentration of antibiotic combinations in the broiler liver, kidney, and muscles. Materials and Methods: The combination of enrofloxacin and tylosin in the liver, kidney, and muscle was validated by HPLC method to find the procedures, processes, equipment, and systems used, consistently provides the appropriate results. The chromatography system consisted of an Octadecyl-silica column of 5 μm in diameter and 150 mm in length with a mobile phase of a mixture of 0.05 M monobasic sodium phosphate (pH 2.5) and acetonitrile (65:35 v/v). The solution was detected at a wavelength of 280 nm, 30°C, a flow rate of 1 mL/min, and an injection volume of 20 μL. The combination antibiotics powder was produced from PT Tekad Mandiri Citra, Bandung, Indonesia, and broiler tissues obtained from day-old chick broilers maintained for 30 days with free antibiotic feed. Results: Validation of a combination solution of enrofloxacin and tylosin shows the linearity values of enrofloxacin and tylosin in the liver, kidney, and muscles as r2=0.9988, r2=0.9999, r2=0.9997, r2=0.9989, r2=0.9978, and r2=0.9962. The accuracy and precision values of enrofloxacin in the liver, kidney, and muscles were 5.53, 6.23, and 6.93, respectively. The values of accuracy and precision of tylosin in the liver, kidney, and muscles were 10.43, 4.63, and 7.16%, respectively. The retention times for enrofloxacin and tylosin were 1.945-2.000 min and 4.175-4.342 min. The limit of detection (LOD) and limit of quantity (LOQ) values for enrofloxacin were 3.03 and 10.1 μg/g, respectively. In contrast, the LOD and LOQ values for tylosin were 9.05 and 30.17 μg/g, respectively. Conclusion: The value of linearity, accuracy, precision, specificity, and sensitivity of the combined solution of enrofloxacin and tylosin showed promising results.

Funder

Universitas Gadjah Mada

Publisher

Veterinary World

Subject

General Veterinary

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3