Perimetry Criteria For Assessing The Effectiveness Of Retinoprotective Therapy

Author:

Dorofeev Dmitry A.1ORCID,Erichev Valery P.2ORCID,Kirilik Elena V.1ORCID,Kokorin Ilya V.3ORCID,Rakova Polina A.4ORCID,Solovieva Olga B.5ORCID,Tsyganov Artem Z.6ORCID,Chemyakina Anastasiya S.4ORCID,Ekgardt Valery F.4ORCID

Affiliation:

1. Chelyabinsk Public Clinical Hospital No. 2, Chelyabinsk, Russia

2. Research Institute of Eye Diseases, Moscow, Russia

3. St. Petersburg National Research University of Information Technology, Mechanics and Optics, Saint-Petersburg, Russia

4. South Ural State Medical University, Chelyabinsk, Russia

5. GEROPHARM LLC, Moscow, Russia

6. S.N. Fyodorov Eye Microsurgery National Medical Research Center, Moscow, Russia

Abstract

Objective — To evaluate the effect of the frequency of retinoprotective therapy courses on perimetry parameters, to compare Octopus 900 perimeter with Octopus 600 perimeter, and to assess threshold perimetry results of G-dynamic versus 24-2 programs. Material and Methods — The study involved 17 patients (34 eyes) diagnosed with primary open-angle glaucoma of advanced stage. Group 1 included subjects receiving a course of Retinalamin every 3 months. Group 2 comprised patients undergoing Retinalamin therapeutics every 6 months. Results — At the onset of the study via G-dynamic and 24-2 programs, we did not observe any statistically significant differences between the groups in mean deviation of retinal photosensitivity (MD) and pattern standard deviation of mean retinal photosensitivity (PSD). However, the absolute values differed between groups and between programs. On average, the differences in MD and PSD values obtained in the photosensitivity study with G-dynamic vs. 24-2 programs were -0.36 dB (CI 95%: -4.27; 3.54) and 0.63 dB (CI 95%: 2.37; -1.11), respectively. Hence, studies performed via 24-2 and G-dynamic programs yielded comparable results (no statistically significant differences). However, they could not be identical due to different spatial arrangement of points in different programs. Conclusion — As a result of conducted treatment, retinal photosensitivity did not exhibit statistically significant changes; however, we observed positive dynamics in both groups in MD and PSD parameters of mean retinal photosensitivity. Different devices (Octopus 600 and Octopus 900 perimeters) and different programs (24-2, G-dynamic) yielded different outcomes due to their technical features and capabilities of reproducibility; however, these differences were not statistically significant.

Publisher

LLC Science and Innovations

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3