A New Iterative Metal Artifact Reduction Algorithm for Both Energy-Integrating and Photon-Counting CT Systems

Author:

Anhaus Julian A.,Heider Maximilian,Killermann Philipp,Hofmann Christian,Mahnken Andreas H.

Abstract

Objectives The aim of this study was to introduce and evaluate a new metal artifact reduction framework (iMARv2) that addresses the drawbacks (residual artifacts after correction and user preferences for image quality) associated with the current clinically applied iMAR. Materials and Methods A new iMARv2 has been introduced, combining the current iMAR with new modular components to remove residual metal artifacts after image correction. The postcorrection image impression is adjustable with user-selectable strength settings. Phantom scans from an energy-integrating and a photon-counting detector CT were used to assess image quality, including a Gammex phantom and anthropomorphic phantoms. In addition, 36 clinical cases (with metallic implants such as dental fillings, hip replacements, and spinal screws) were reconstructed and evaluated in a blinded and randomized reader study. Results The Gammex phantom showed lower HU errors compared with the uncorrected image at almost all iMAR and iMARv2 settings evaluated, with only minor differences between iMAR and the different iMARv2 settings. In addition, the anthropomorphic phantoms showed a trend toward lower errors with higher iMARv2 strength settings. On average, the iMARv2 strength 3 performed best of all the clinical reconstructions evaluated, with a significant increase in diagnostic confidence and decrease in artifacts. All hip and dental cases showed a significant increase in diagnostic confidence and decrease in artifact strength, and the improvements from iMARv2 in the dental cases were significant compared with iMAR. There were no significant improvements in the spine. Conclusions This work has introduced and evaluated a new method for metal artifact reduction and demonstrated its utility in routine clinical datasets. The greatest improvements were seen in dental fillings, where iMARv2 significantly improved image quality compared with conventional iMAR.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3