Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®

Author:

Martina Jerson R.1,Westerhof Berend E.2,van Goudoever Jeroen3,de Beaumont Edouard M. F. H.4,Truijen Jasper5,Kim Yu-Sok5,Immink Rogier V.6,Jöbsis Dorothea A.7,Hollmann Markus W.8,Lahpor Jaap R.9,de Mol Bas A. J. M.10,van Lieshout Johannes J.11

Affiliation:

1. Research Scientist, Department of Cardiothoracic Surgery, University Medical Center Utrecht, Utrecht, The Netherlands.

2. Clinical Program Manager, BMEYE B.V., Amsterdam, The Netherlands, and Senior Research Fellow, Laboratory for Clinical Cardiovascular Physiology, AMC Heart Failure Research Center, Amsterdam, The Netherlands.

3. Vice President of Resarch and Development, BMEYE B.V., and Senior Research Fellow, Laboratory for Clinical Cardiovascular Physiology, AMC Heart Failure Research Center.

4. Anesthesiologist, Department of Anesthesiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.

5. Research Fellow, Laboratory for Clinical Cardiovascular Physiology, AMC Heart Failure Research Center.

6. Anesthesiologist.

7. Researcher.

8. Professor, Department of Anesthesiology, Academic Medical Center, University of Amsterdam.

9. Professor, Department of Cardiothoracic Surgery, University Medical Center Utrecht.

10. Professor, Department of Cardiothoracic Surgery, Academic Medical Center, University of Amsterdam, and Professor, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.

11. Professor, School of Biomedical Sciences, University of Nottingham Medical School, Queen's Medical Centre, Nottingham, United Kingdom, and Director, Acute Medical Care Unit, Department of Internal Medicine, Academic Medical Center, University of Amsterdam, and Director, Laboratory for Clinical Cardiovascular Physiology, AMC Heart Failure Research Center.

Abstract

Background If invasive measurement of arterial blood pressure is not warranted, finger cuff technology can provide continuous and noninvasive monitoring. Finger and radial artery pressures differ; Nexfin® (BMEYE, Amsterdam, The Netherlands) measures finger arterial pressure and uses physiologic reconstruction methodologies to obtain values comparable to invasive pressures. Methods Intra-arterial pressure (IAP) and noninvasive Nexfin arterial pressure (NAP) were measured in cardiothoracic surgery patients, because invasive pressures are available. NAP-IAP differences were analyzed during 30 min. Tracking was quantified by within-subject precision (SD of individual NAP-IAP differences) and correlation coefficients. The ranges of pressure change were quantified by within-subject variability (SD of individual averages of NAP and IAP). Accuracy and precision were expressed as group average ± SD of the differences and considered acceptable when smaller than 5 ± 8 mmHg, the Association for the Advancement of Medical Instrumentation criteria. Results NAP and IAP were obtained in 50 (34-83 yr, 40 men) patients. For systolic, diastolic, mean arterial, and pulse pressure, median (25-75 percentiles) correlation coefficients were 0.96 (0.91-0.98), 0.93 (0.87-0.96), 0.96 (0.90-0.97), and 0.94 (0.85-0.98), respectively. Within-subject precisions were 4 ± 2, 3 ± 1, 3 ± 2, and 3 ± 2 mmHg, and within-subject variations 13 ± 6, 6 ± 3, 9 ± 4, and 7 ± 4 mmHg, indicating precision over a wide range of pressures. Group average ± SD of the NAP-IAP differences were -1 ± 7, 3 ± 6, 2 ± 6, and -3 ± 4 mmHg, meeting criteria. Differences were not related to mean arterial pressure or heart rate. Conclusion Arterial blood pressure can be measured noninvasively and continuously using physiologic pressure reconstruction. Changes in pressure can be followed and values are comparable to invasive monitoring.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference33 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3