Invasive and Concomitant Noninvasive Intraoperative Blood Pressure Monitoring

Author:

Wax David B.1,Lin Hung-Mo1,Leibowitz Andrew B.2

Affiliation:

1. Associate Professor, Department of Anesthesiology.

2. Professor, Departments of Anesthesiology and Surgery, Mount Sinai School of Medicine, New York, New York.

Abstract

Background Noninvasive (NIBP) and intraarterial (ABP) blood pressure monitoring are used under different circumstances and may yield different values. The authors endeavored to characterize these differences and hypothesized that there could be differences in interventions associated with the use of ABP alone ([ABP]) versus ABP in combination with NIBP ([ABP+NIBP]). Methods Simultaneous measurements of ABP and NIBP made during noncardiac cases were extracted from electronic anesthesia records; the differences were subjected to regression analysis. Records of blood products, vasopressors, and antihypertensives administered were also extracted, and associations between the use of these therapies and monitoring strategy ([ABP] vs. [ABP+NIBP]) were tested using univariate, multivariate, and propensity score matched analyses. Results Among 24,225 cases, 63% and 37% used [ABP+NIBP] and [ABP], respectively. Systolic NIBP was likely to be higher than ABP when ABP was less than 111 mmHg and lower than ABP otherwise. Among patients with hypotension, transfusion occurred in 27% versus 43% of patients in the [ABP+NIBP] versus [ABP] group, respectively (odds ratio = 0.4; 95% CI 0.35-0.46), and 7% versus 18% of patients in the [ABP+NIBP] versus [ABP] group received vasopressor infusions, respectively (P < 0.01). Among hypertensive patients, 12% versus 44% of those in the [ABP+NIBP] versus [ABP] group received antihypertensive agents, respectively (P < 0.01). Conclusions NIBP was generally higher than ABP during periods of hypotension and lower than ABP during periods of hypertension. The use of NIBP measurements to supplement ABP measurements was associated with decreased use of blood transfusions, vasopressor infusions, and antihypertensive medications compared with the use of ABP alone.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference19 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3