Background Cerebral oximetry is a noninvasive technology using near-infrared spectroscopy (NIRS) to estimate regional cerebral oxygen saturation. Although NIRS cerebral oximetry is being increasingly used in many clinical settings, interdevice technologic differences suggest potential variation in the ability to accurately acquire brain oxygenation signals. The primary objective of this study was to determine if NIRS-derived regional cerebral oxygen saturation measurements accurately account for oxygen saturation contamination from extracranial tissue. Methods Twelve healthy volunteers had each of three NIRS devices (FORE-SIGHT [CAS Medical Systems Inc; Brandford, CT], INVOS 5100C-PB [Covidien; Boulder, CO], and EQUANOX Classic 7600 [Nonin Medical Inc; Plymouth, MN]) randomly applied to the forehead. After this, a circumferential pneumatic head cuff was positioned such that when inflated, hypoxia-ischemia would be produced in the extracranial scalp tissue beneath the NIRS cerebral oximeters. Comparisons among the three devices were made of the NIRS measurements before and following hypoxia-ischemia produced in the scalp tissue with inflation of the head cuff. Results The induction of extracranial hypoxia-ischemia resulted in a significant reduction in regional cerebral oxygen saturation measurements in all three NIRS devices studied. At 5 min postinflation of the pneumatic head cuff, the INVOS demonstrated a 16.6 ± 9.6% (mean ± SD) decrease from its baseline (P = 0.0001), the FORE-SIGHT an 11.8 ± 5.3% decrease from its baseline (P < 0.0001), and the EQUANOX a 6.8 ± 6.0% reduction from baseline (P = 0.0025). Conclusions Extracranial contamination appears to significantly affect NIRS measurements of cerebral oxygen saturation. Although the clinical implications of these apparent inaccuracies require further study, they suggest that the oxygen saturation measurements provided by cerebral oximetry do not solely reflect that of the brain alone.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference24 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3