Adaptive Support Ventilation

Author:

Sulemanji Demet1,Marchese Andrew2,Garbarini Paul3,Wysocki Marc4,Kacmarek Robert M.5

Affiliation:

1. Clinical Research Fellow, Department of Anesthesiology and Critical Care, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts.

2. Research Associate, Department of Respiratory Care, Massachusetts General Hospital, Boston, Massachusetts.

3. Clinical Applications Manager.

4. Head of Medical Research, Hamilton Medical, Switzerland.

5. Professor of Anesthesia, Department of Anesthesiology and Critical Care, and Director of Respiratory Care, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts.

Abstract

Background Adaptive support ventilation (ASV) allows the clinician to set a maximum plateau pressure (PP) and automatically adjusts tidal volume to keep PP below the set maximum. Methods ASV was compared to a fixed tidal volume of 6 ml/kg. ASV determined the respiratory rate and tidal volume based on its algorithms. Maximum airway pressure limit was 28 cm H2O in ASV. Six sets of lung mechanics were simulated for two ideal body weights: 60 kg, Group I; 80 kg, Group II. Positive end expiratory pressure was 8, 12, and 16 cm H2O, and target minute volume 120%, 150%, and 200% of predicted minute volume. Results ASV "sacrificed" tidal volume and minute ventilation to maintain PP in 9 (17%) of 54 scenarios in Group I and 20 (37%) of 54 scenarios in Group II. In Group I, the number of scenarios with PP of 28 cm H2O or more was 14 for ASV (26%) and 19 for 6 ml/kg (35%). In these scenarios, mean PP were ASV 28.8 +/- 0.86 cm H2O (min 28, max 30.3) and 6 ml/kg 33.01 +/- 3.48 cm H2O (min 28, max 37.8) (P = 0.000). In group II, the number of scenarios PP of 28 cm H2O or more was 10 for ASV (19%) and 21 for 6 ml/kg (39%). In these cases, mean PP values were ASV 28.78 +/- 0.54 cm H2O (min 28, max 29.6) and 6 ml/kg 32.66 +/- 3.37 cm H2O (min 28.2, max 38.2) (P = 0.000). Conclusion In a lung model with varying mechanics, ASV is better able to prevent the potential damaging effects of excessive PP (greater than 28 cm H2O) than a fixed tidal volume of 6 ml/kg by automatically adjusting airway pressure, resulting in a decreased tidal volume.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference29 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3