Guided trocar insertion in highly myopic eyes

Author:

Savastano Alfonso12,Bernardinelli Patrizio12ORCID,De Vico Umberto1,Amorelli Giulia Maria12,Niutta Matteo3,Rizzo Stanislao124

Affiliation:

1. Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy

2. Università Cattolica del Sacro Cuore, Rome, Italy

3. Ophthalmology Complex Operative Unit, Campus Bio Medico University, 00128 Rome, Italy

4. Consiglio Nazionale delle Ricerche, Istituto di Neuroscienze, Pisa – Italy

Abstract

Abstract Purpose: to demonstrate through a diagnostic test used as a new preoperative assessment, that trocar insertion for pars plana vitrectomy could be safely placed at a distance greater than 4.0 mm in highly myopic eyes to facilitate the surgical maneuvers. Methods: 30 eyes of 30 patients were tested with a biometer for the axial length measurement and with ultrasound biomicroscopy (UBM) to measure the pars plana length. Pars plana lengths of highly myopic eyes were then compared with those of emmetropic eyes. The surgeon also measured the pars plana of highly myopic eyes intraoperatively and compared it with ultrasound measurements to assess UBM reliability. Results: The mean AXL was 23.81mm (SD ±0.30) in the control group and 31.11 mm (SD ±0.56) in the myopic group. The mean pars plana length was 4.96 mm (SD ±0.19) in control eyes and 6.65 (SD ±0.36) in myopic eyes. An extremely significant statistical difference (p < 0.001) was obtained by comparing the length of pars plana between control eyes and myopic eyes. The results of pars plana measurements were 6.65 mm SD ±0.36 (UBM) and 6.66 mm SD ±0.34 (intraoperative measurements) in myopic eyes. The statistical comparison of the measurements in these two groups did not give a statistically significant result (p = 0.950). Conclusions: UBM is a reliable technique to calculate the length of pars plana in highly myopic eyes, where this parameter is significantly greater than that of emmetropic eyes. Trocars insertion for pars plana vitrectomy may be performed, in eyes with axial length greater than 30mm, in relative safety at a distance to limbus higher than 4mm.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3