Association of Intravenous Fluorescein Angiography and Adaptive Optics Imaging in Diabetic Retinopathy: A Prospective Case Series

Author:

Huang Ryan S.1,Mihalache Andrew1,Popovic Marko M.2,Munn Colyn34,Balas Michael1,Issa Mariam1,Melo Isabela Martins2,Friedman Alon34,Wright Tom5,Yan Peng25,Muni Rajeev H.26

Affiliation:

1. Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada

2. Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada

3. Emagix Inc., Halifax, Nova Scotia, Canada

4. Department of Medical Neuroscience, Faculty of Medicine, Dalhousie University, Halifax, Nova Scotia, Canada

5. Kensington Vision and Research Centre, Kensington Eye Institute, Toronto, Ontario, Canada

6. Department of Ophthalmology, St. Michael’s Hospital/Unity Health Toronto, Toronto, Ontario, Canada

Abstract

Purpose: To our knowledge, we present the first case series investigating the relationship between adaptive optics (AO) imaging and intravenous fluorescein angiography (IVFA) parameters in patients with diabetic retinopathy (DR). Methods: Consecutive patients with DR over the age of 18 years presenting to a single centre in Toronto, Canada from 2020-2021 were recruited. AO was performed with the RTX1 camera (Imagine Eyes, Orsay, France) at retinal eccentricities of 2° and 4°. IVFA was assessed with the artificial intelligence-based RETICAD system to extract blood flow, perfusion, and blood-retinal barrier (BRB) permeability at the same retinal locations. Correlations between AO and IVFA parameters were calculated using Pearson’s correlation coefficient. Results: Across nine cases, a significant positive correlation existed between photoreceptor spacing on AO and BRB permeability (r=0.303, p=0.027), as well as perfusion (r=0.272, p=0.049) on IVFA. When stratified by location, a significant positive correlation between photoreceptor dispersion and both BRB permeability and perfusion (r=0.770, p=0.043; r=0.846, p=0.034, respectively) was observed. Cone density was also negatively correlated with BRB permeability (r=-0.819, p=0.046). Conclusion: Photoreceptor spacing on AO was significantly correlated with BRB permeability and perfusion on IVFA in patients with DR. Future studies with larger sample sizes are needed to understand the relationship between AO and IVFA parameters in diverse patient populations.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3