Impact of Radial Arterial Location on Catheter Lifetime in ICU Surgical Intensive Care

Author:

Marie Damien1,Dahyot-Fizelier Claire,Barrau Stéphanie1,Boisson Matthieu123,Frasca Denis123,Jamet Angeline1,Chauvet Stéphane1,Ferrand Nathan1,Pichot Amélie1,Mimoz Olivier,Kerforne Thomas14

Affiliation:

1. Department of Anesthesia, Intensive Care and Perioperative Medicine, University Hospital of Poitiers, Poitiers, France.

2. Université de Poitiers, Faculté de Médecine, Poitiers, France.

3. INSERM U1070, Pharmacologie des Agents anti-infectieux, Poitiers, France.

4. INSERM U1082 (IRTOMIT), Poitiers, France.

Abstract

OBJECTIVES: The use of arterial catheters is frequent in intensive care for hemodynamic monitoring of patients and for blood sampling, but they are often removed because of dysfunction. The primary objective is to compare the prevalence of radial arterial catheter dysfunction according to location in relation to the radiocarpal joint in intensive care patients. DESIGN: Prospective randomized, controlled, single-center study. SETTING: The surgical ICU of the university hospital of Poitiers in France. PATIENTS: From January 2016 to April 2017, all patients over 18 years old admitted to the surgical ICU and requiring an arterial catheter were included. INTERVENTIONS: Randomization into two groups: catheter placed near the wrist (within 4 cm of the radiocarpal joint) and catheter placed away the wrist. The primary endpoint was the prevalence of dysfunction. We also compared the prevalence of infection and colonization. MEASUREMENTS AND MAIN RESULTS: One hundred seven catheters were analyzed (14 failed placements with no difference between the two groups, and 16 catheters excluded for missing data), with 58 catheters in near the wrist group and 49 in away the wrist group. We did not find any significant difference in the number of catheter dysfunctions between the two groups (p = 0.56). The prevalence density of catheter dysfunction was 30.5 of 1,000 catheter days for near the wrist group versus 26.7 of 1,000 catheter days for away the wrist group. However, we observed a significant difference in terms of catheter-related infection in favor of away the wrist group (p = 0.04). In addition, distal positioning of the catheter was judged easier by the physicians. CONCLUSIONS: The distal or proximal position of the arterial catheter in the radial position has no influence on the occurrence of dysfunction. However, there may be an association with the prevalence of infections.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Critical Care and Intensive Care Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3