Magnetic Resonance Imaging in Patients with Cochlear Implants without Magnet Removal: A Radiology-Administered Protocol to Enhance Operational Efficiency and Improve Workflow

Author:

Johnson B. Jake1,Macielak Robert J.1,Watson Robert E.2,Heimer Jean M.2,Wiste Britany J.2,Lane John I.2,Edmonson Heidi A.2,Carlson Matthew L.

Affiliation:

1. Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic, Rochester, Minnesota

2. Department of Radiology, Mayo Clinic, Rochester, Minnesota

Abstract

ObjectiveTo describe the development, implementation, and validation of a radiology-administered protocol to obtain magnetic resonance imaging (MRI) in patients with cochlear implants and auditory brainstem implants without magnet removal.Study DesignRetrospective review and description of novel care pathway.MethodsA radiology-administered protocol was designed based on careful input from the radiology safety committee and neurotology. Radiology technologist training modules, consent instructions, patient educational material, clinical audits, and other safeguards were implemented, with samples provided in this report. The primary outcomes measured included instances of magnet displacement during MRI and premature termination of MRI studies secondary to pain.ResultsBetween June 19, 2018, and October 12, 2021, 301 implanted ears underwent MRI without magnet removal, including 153 devices housing diametric MRI-conditional magnets, and 148 implants with conventional axial (i.e., nondiametric) magnets. Among cases with diametric MRI-conditional magnets, all studies were completed without magnet dislodgement or need to terminate imaging early due to pain. Among cases with conventional axial (nondiametric) magnets, 29 (19.6%) MRI studies were stopped prematurely secondary to pain or discomfort; the overall rate of this event was 9.6% (29 of 301) among the entire study cohort. In addition, 6.1% (9 of 148) experienced confirmed magnet displacement despite headwrap placement; the overall rate among all cases was 3.0% (9 of 301). Eight of these patients received successful external magnet reseating through manual pressure on the external scalp without surgery, and one required surgical replacement of the magnet in the operating room. There were no documented instances of hematoma, infection, device or magnet extrusion, internal device movement (i.e., gross receiver-stimulator migration), or device malfunction in this cohort related to MRI.ConclusionsWe present the successful implementation of a radiology-administered protocol designed to streamline care for cochlear implant and auditory brainstem implant recipients who require MRI and ease clinical demands for otolaryngology providers. Examples of resources developed, including a process map, radiology training modules, consent instructions, patient educational materials, clinical audit, and other procedural safety measures are provided so interested groups may consider adapting and implementing related measures according to need.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Sensory Systems,Otorhinolaryngology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3