Influence of the Electrode Montage to Detect Ocular Vestibular Evoked Myogenic Potentials

Author:

Mat Quentin,Deggouj Naïma1,Duterme Jean-Pierre2,Tainmont Sophie2,Lelubre Christophe,Manto Mario

Affiliation:

1. Department of Otorhinolaryngology and Head and Neck Surgery, Cliniques Universitaires Saint-Luc, UCLouvain (UCL), Brussels 1200, Belgium

2. Department of Otorhinolaryngology, C.H.U. Charleroi, Charleroi 6042, Belgium

Abstract

Objective To compare ocular vestibular evoked myogenic potentials (oVEMPs) obtained with three different electrode montages (infra-orbital vs belly-tendon vs chin) in a group of healthy subjects. To assess the electrical activity recorded at the level of the reference electrode in the belly-tendon and chin montages. Study Design Prospective study. Setting Tertiary referral center. Patients Twenty-five healthy adult volunteers. Intervention(s) Each ear was tested separately via air-conducted sound (500 Hz Narrow Band CE-Chirps at 100 dB nHL) for recording contralateral myogenic responses. Recording conditions were randomized. Main Outcome Measure(s) n1-p1 amplitudes values, interaural amplitude asymmetry ratios (ARs) and response rates. Results The belly-tendon electrode montage (BTEM) produced larger amplitudes than the chin (p = 0.008) and the IOEM (infra-orbital electrode montage; p < 0.001). The chin montage displayed larger amplitudes than the IOEM (p < 0.001). The interaural amplitude asymmetry ratios (ARs) were not affected by the different electrode montages (p = 0.549). In 100% of cases, oVEMPs were detected bilaterally with the BTEM which is higher than with the chin and the IOEM (p < 0.001; p = 0.020, respectively). We did not record any VEMP when placing the active electrode on the contralateral internal canthus or the chin and the reference electrode on the dorsum of the hand. Conclusions The BTEM increased the amplitudes recorded and response rate in healthy subjects. No positive or negative reference contamination was observed with the belly-tendon or chin montages.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Sensory Systems,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3