Effect of Light Intensity on the Relative Afferent Pupillary Defect in Unilateral Neuro-ophthalmic Pathology

Author:

Negi Rahul,Raviselvan Munispriyan,Yarravarapu Divyank1,Chillakala Koteswararao1,Durai C. V. Reena,Baskar Juhi1,Jain Ashish1,Bisht Karan1,Bhate Manjushree2,Bharadwaj Shrikant R.

Affiliation:

1. Centre for Technology Innovation, L V Prasad Eye Institute, Hyderabad, Telangana, India

2. Jasti V. Ramanamma Children's Eye Care Centre, Child Sight Institute, L V Prasad Eye Institute, Hyderabad, Telangana, India

Abstract

ABSTRACT SIGNIFICANCE Objective pupillometry with standardized light intensities allows a comprehensive assessment of the relative afferent pupillary defect in patients with unilateral neuro-ophthalmic pathology. PURPOSE This study aimed to determine the impact of varying light intensities on the grade of relative afferent pupillary defect in unilateral neuro-ophthalmic pathology vis-à-vis healthy controls. METHODS Monocular pupillary light reflexes of 20 controls (14 to 50 years) and 31 cases (12 to 72 years) with clinically diagnosed relative afferent pupillary defect were measured thrice using 1-second-long light pulses, followed by 3 seconds of darkness, at eight light intensities (6.4 to 1200 lux) using objective pupillometry. The relative afferent pupillary defect was quantified as the ratio of the percentage change in the direct light reflexes of the left and right eyes. Its change with light intensity was described using standard exponential fits. RESULTS The median (25th to 75th interquartile range) defect score of 54.8% cases decreased from baseline values of 1.58 (1.25 to 1.87) for right eye pathology and 0.45 (0.39 to 0.55) for left eye pathology to saturation values of 1.18 (1.05 to 1.31) and 0.98 (0.95 to 1.06), respectively, at light intensities between 56.9 and 300.5 lux. Like controls (1.01 [1.00 to 1.06]), the defect scores of the remaining 45.2% cases were constant with light intensity at 1.23 (1.18 to 1.46) and 0.87 (0.86 to 0.89) for right and left eye pathologies, respectively. CONCLUSIONS Relative afferent pupillary defects may decrease with test light intensity in a significant proportion of patients with unilateral neuro-ophthalmic pathology. This highlights the importance of objective pupillometry with standardization light intensities for clinical assessment of afferent pupillary defects.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Optometry,Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3