Evaluation of a Pilot Protocol for Detecting Infant Hyperopia

Author:

Morrison Ann M.,Mutti Donald O.1

Affiliation:

1. The Ohio State University College of Optometry, Columbus, Ohio

Abstract

SIGNIFICANCEHighly hyperopic children are at greater risk for developing conditions such as strabismus, amblyopia, and early literacy and reading problems. High hyperopia is a common finding in infants in a pediatric medical practice, and early detection can be done effectively in that setting with tropicamide autorefraction.PURPOSEThis study aimed to evaluate the effectiveness of a pilot screening program to detect high hyperopia in 2-month-old infants in a pediatric medical practice in Columbus, Ohio.METHODSCycloplegic refractive error (1% tropicamide) was measured by retinoscopy and autorefraction with the Welch Allyn SureSight (Welch Allyn/Hillrom, Skaneateles Falls, NY) in 473 infants (55.4% female) who were undergoing their 2-month well-baby visit at their pediatrician's medical practice. Cycloplegic retinoscopy (1% cyclopentolate) was repeated at a subsequent visit in 35 infants with ≥+5.00 D hyperopia in the most hyperopic meridian during the screening.RESULTSTwenty-eight infants (5.9%) had high hyperopia (spherical equivalent, ≥+5.00 D), and 61 (12.9%) had high hyperopia (≥+5.00 D in at least one meridian of at least one eye) by retinoscopy with 1% tropicamide. The mean ± standard deviation spherical equivalent tropicamide cycloplegic refractive error measured with retinoscopy was +2.54 ± 1.54 D (range, −3.25 to +7.00 D) and with SureSight was +2.29 ± 1.64 D (range, −2.90 to +7.53 D). Retinoscopy done using 1% cyclopentolate was 0.44 ± 0.54 D more hyperopic in spherical equivalent than with 1% tropicamide (P< .001).CONCLUSIONSHigh hyperopia was a common finding in 2-month-old infants in a pediatric medical setting that could be detected effectively by cycloplegic autorefraction using tropicamide. Greater cooperation between pediatric primary vision and medical care could lead to effective vision screenings designed to detect high hyperopia in infants.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Optometry,Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3