Initial Experience of an Anesthesiology-based Service for Perioperative Management of Pacemakers and Implantable Cardioverter Defibrillators

Author:

Rooke G. Alec1,Lombaard Stefan A.1,Van Norman Gail A.1,Dziersk Jörg1,Natrajan Krishna M.1,Larson Lyle W.1,Poole Jeanne E.1

Affiliation:

1. From the Department of Anesthesiology and Pain Medicine (G.A.R., S.A.L., G.A.V.N., J.D., K.M.N.) and Division of Cardiology, Department of Medicine (L.W.L., J.E.P.), University of Washington, Seattle, Washington.

Abstract

Abstract Background Management of cardiovascular implantable electronic devices (CIEDs), including pacemakers and implantable cardioverter defibrillators, for surgical procedures is challenging due to the increasing number of patients with CIEDs and limited availability of trained providers. At the authors’ institution, a small group of anesthesiologists were trained to interrogate CIEDs, devise a management plan, and perform preoperative and postoperative programming and device testing whenever necessary. Methods Patients undergoing surgery between October 1, 2009 and June 30, 2013 at the University of Washington Medical Center were included in a retrospective chart review to determine the number of devices actively managed by the Electrophysiology/Cardiology Service (EPCS) versus the Anesthesiology Device Service (ADS), changes in workload over time, surgical case delays due to device management, and errors and problems encountered in device programming. Results The EPCS managed 254 CIEDs, the ADS managed 548, and 227 by neither service. Over time, the ADS providers managed an increasing percentage of devices with decreasing supervision from the EPCS. Only two CIEDs managed by the ADS required immediate assistance from the EPCS. Patients who were unstable postoperatively were referred to the EPCS. Although numerous issues in programming were encountered, primarily when restoring demand pacing after programming asynchronous pacing for surgery, no patient harm resulted from ADS or EPCS management of CIEDs. Conclusions An ADS can provide safe CIED management for surgery, but it requires specialized provider training and strong support from the EPCS. Due to the complexity of CIED management, an ADS will likely only be feasible in high-volume settings.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3