Abstract
Purpose:
The objective of this study was to evaluate the association between comprehensive cardiac rehabilitation (CCR) completion and long-term clinical outcomes in patients with cardiac implantable electronic devices (CIED).
Methods:
This retrospective cohort study included 834 patients with CIED who participated in CCR, which included a cardiopulmonary exercise test or 6-min walk test. Patients with a left ventricular ejection fraction ≤40%, predicted peak oxygen uptake ≤80%, or B-type natriuretic peptide level ≥80 pg/mL were eligible. The primary outcome was all-cause mortality.
Results:
After excluding 241 patients with duplicate records and 69 who underwent CCR in the outpatient department, the data of 524 patients were analyzed. Mean age was 64 ± 15 yr, 389 (74%) patients were men, left ventricular ejection fraction was 31 ± 15%, and 282 (54%) patients had a history of hospitalization for worsening heart failure.. Of the patients referred for CCR, 294 (56%) completed the program, and an additional 230 patients started but did not complete CCR. Over a 3.7-yr median follow-up period, all-cause deaths occurred in 156 (30%) patients. Completers had lower all-cause mortality rates than non-completers (log-rank 15.77, P < .001). After adjusting for prognostic baseline characteristics, completers had 58% lower all-cause mortality risks than non-completers (HR = 0.42; 95% CI, 0.27-0.64, P < .001).
Conclusions:
Three-mo CCR program completion was associated with lower death risks in patients with CIED. New programs or management methods are needed to decrease death risks, especially for those who cannot complete CCR programs.