ASSESSMENT OF ABNORMAL SKELETAL MUSCLE PERFUSION BY CONTRAST-ENHANCED ULTRASOUND WITH PARAMETRIC IMAGING IN RATS AFTER SEVERE INJURY, HEMORRHAGIC SHOCK, AND WHOLE BLOOD RESUSCITATION

Author:

St. John Alexander1,Wang Xu1,Ringgold Kristyn1,Lindner Jonathan2,White Nathan1,Stern Susan1,López José3

Affiliation:

1. Department of Emergency Medicine, University of Washington School of Medicine, Seattle, Washington

2. Division of Cardiovascular Medicine, University of Virginia School of Medicine, Charlottesville, Virginia

3. Bloodworks Northwest Research Institute, Seattle, Washington

Abstract

ABSTRACT Background: After severe injury, optical measures of microvascular blood flow (MBF) decrease and do not normalize with resuscitation to normal blood pressure. These changes are associated with organ dysfunction, coagulopathy, and death. However, the pathophysiology is not well understood. Several possible pathways could also contribute to the development of trauma-induced coagulopathy (TIC). A small-animal model of trauma-related MBF derangement that persists after resuscitation and includes TIC would facilitate further study. Parametric contrast-enhanced ultrasound (CEUS) is particularly advantageous in this setting, because it noninvasively assesses MBF in large, deep vascular beds. We sought to develop such a model, measuring MBF with CEUS. Methods: Sixteen male Sprague-Dawley rats were anesthetized, ventilated, and cannulated. Rats were subjected to either no injury (sham group) or a standardized polytrauma and pressure-targeted arterial catheter hemorrhage with subsequent whole blood resuscitation (trauma group). At prespecified time points, CEUS measurements of uninjured quadriceps muscle, viscoelastic blood clot strength, and complete blood counts were taken. Results: After resuscitation, blood pressure normalized, but MBF decreased and remained low for the rest of the protocol. This was primarily driven by a decrease in blood volume with a relative sparing of blood velocity. Viscoelastic blood clot strength and platelet count also decreased and remained low throughout the protocol. Conclusion: We present a rat model of MBF derangement in uninjured skeletal muscle and coagulopathy after polytrauma that persists after resuscitation with whole blood to normal macrohemodynamics. Parametric CEUS analysis shows that this change is primarily due to microvascular obstruction. This platform can be used to develop a deeper understanding of this important process.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Critical Care and Intensive Care Medicine,Emergency Medicine

Reference33 articles.

1. Hemodynamic coherence and the rationale for monitoring the microcirculation;Crit Care,2015

2. Monitoring microcirculation in critical illness;Curr Opin Crit Care,2016

3. Distribution of trauma deaths in a province of Korea: is “trimodal” distribution relevant today?;Yonsei Med J,2020

4. Acute traumatic coagulopathy;J Trauma,2003

5. Acute traumatic coagulopathy;Curr Opin Crit Care,2014

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3