Source-level Cortical Power Changes for Xenon and Nitrous Oxide–induced Reductions in Consciousness in Healthy Male Volunteers

Author:

Pelentritou Andria1,Kuhlmann Levin1,Cormack John1,Mcguigan Steven1,Woods Will1,Muthukumaraswamy Suresh1,Liley David1

Affiliation:

1. From the Centre for Human Psychopharmacology (A.P., L.K., D.L.) and the Centre for Mental Health (W.W.), Swinburne University of Technology, Melbourne, Australia; the Faculty of Information Technology, Monash University, Melbourne, Australia (L.K.); the Department of Anaesthesia and Pain Management, St. Vincent’s Hospital Melbourne, Melbourne, Australia (J.C., S.M.); the School of Pharmacy, The U

Abstract

Abstract Background Investigations of the electrophysiology of gaseous anesthetics xenon and nitrous oxide are limited revealing inconsistent frequency-dependent alterations in spectral power and functional connectivity. Here, the authors describe the effects of sedative, equivalent, stepwise levels of xenon and nitrous oxide administration on oscillatory source power using a crossover design to investigate shared and disparate mechanisms of gaseous xenon and nitrous oxide anesthesia. Methods Twenty-one healthy males underwent simultaneous magnetoencephalography and electroencephalography recordings. In separate sessions, sedative, equivalent subanesthetic doses of gaseous anesthetic agents nitrous oxide and xenon (0.25, 0.50, and 0.75 equivalent minimum alveolar concentration–awake [MACawake]) and 1.30 MACawake xenon (for loss of responsiveness) were administered. Source power in various frequency bands were computed and statistically assessed relative to a conscious/pre-gas baseline. Results Observed changes in spectral-band power (P < 0.005) were found to depend not only on the gas delivered, but also on the recording modality. While xenon was found to increase low-frequency band power only at loss of responsiveness in both source-reconstructed magnetoencephalographic (delta, 208.3%, 95% CI [135.7, 281.0%]; theta, 107.4%, 95% CI [63.5, 151.4%]) and electroencephalographic recordings (delta, 260.3%, 95% CI [225.7, 294.9%]; theta, 116.3%, 95% CI [72.6, 160.0%]), nitrous oxide only produced significant magnetoencephalographic high-frequency band increases (low gamma, 46.3%, 95% CI [34.6, 57.9%]; high gamma, 45.7%, 95% CI [34.5, 56.8%]). Nitrous oxide—not xenon—produced consistent topologic (frontal) magnetoencephalographic reductions in alpha power at 0.75 MACawake doses (44.4%; 95% CI [−50.1, −38.6%]), whereas electroencephalographically nitrous oxide produced maximal reductions in alpha power at submaximal levels (0.50 MACawake, −44.0%; 95% CI [−48.1,−40.0%]). Conclusions Electromagnetic source-level imaging revealed widespread power changes in xenon and nitrous oxide anesthesia, but failed to reveal clear universal features of action for these two gaseous anesthetics. Magnetoencephalographic and electroencephalographic power changes showed notable differences which will need to be taken into account to ensure the accurate monitoring of brain state during anaesthesia. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference49 articles.

1. Molecular and neuronal substrates for general anaesthetics.;Nat Rev Neurosci,2004

2. General anaesthesia: from molecular targets to neuronal pathways of sleep and arousal.;Nat Rev Neurosci,2008

3. Electroencephalogram signatures of loss and recovery of consciousness from propofol.;Proc Natl Acad Sci U S A,2013

4. Clinical electroencephalography for anesthesiologists: Part I: Background and basic signatures.;Anesthesiology,2015

5. Fast oscillatory EEG activity induced by analgesic concentrations of nitrous oxide in man.;Anesth Analg,1981

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3