Intrathecal Morphine versus Intrathecal Hydromorphone for Analgesia after Cesarean Delivery

Author:

Sharpe Emily E.1,Molitor Rochelle J.1,Arendt Katherine W.1,Torbenson Vanessa E.1,Olsen David A.1,Johnson Rebecca L.1,Schroeder Darrell R.1,Jacob Adam K.1,Niesen Adam D.1,Sviggum Hans P.1

Affiliation:

1. From the Departments of Anesthesiology and Peri-operative Medicine (E.E.S., R.J.M., K.W.A., D.A.O., R.L.J., A.K.J., A.D.N., H.P.S.), Obstetrics and Gynecology (V.E.T.), and Health Sciences Research (D.R.S.), Mayo Clinic, Rochester, Minnesota.

Abstract

Abstract Background Intrathecal opioids are routinely administered during spinal anesthesia for postcesarean analgesia. The effectiveness of intrathecal morphine for postcesarean analgesia is well established, and the use of intrathecal hydromorphone is growing. No prospective studies have compared the effectiveness of equipotent doses of intrathecal morphine versus intrathecal hydromorphone as part of a multimodal analgesic regimen for postcesarean analgesia. The authors hypothesized that intrathecal morphine would result in superior analgesia compared with intrathecal hydromorphone 24 h after delivery. Methods In this single-center, double-blinded, randomized trial, 138 parturients undergoing scheduled cesarean delivery were randomized to receive 150 µg of intrathecal morphine or 75 µg of intrathecal hydromorphone as part of a primary spinal anesthetic and multimodal analgesic regimen; 134 parturients were included in the analysis. The primary outcome was the numerical rating scale score for pain with movement 24 h after delivery. Static and dynamic pain scores, nausea, pruritus, degree of sedation, and patient satisfaction were assessed every 6 h for 36 h postpartum. Total opioid consumption was recorded. Results There was no significant difference in pain scores with movement at 24 h (intrathecal hydromorphone median [25th, 75th] 4 [3, 5] and intrathecal morphine 3 [2, 4.5]) or at any time point (estimated difference, 0.5; 95% CI, 0 to 1; P = 0.139). Opioid received in the first 24 h did not differ between groups (median [25th, 75th] oral morphine milligram equivalents for intrathecal hydromorphone 30 [7.5, 45.06] vs. intrathecal morphine 22.5 [14.0, 37.5], P = 0.769). From Kaplan–Meier analysis, the median time to first opioid request was 5.4 h for hydromorphone and 12.1 h for morphine (log-rank test P = 0.200). Conclusions Although the hypothesis was that intrathecal morphine would provide superior analgesia to intrathecal hydromorphone, the results did not confirm this. At the doses studied, both intrathecal morphine and intrathecal hydromorphone provide effective postcesarean analgesia when combined with a multimodal analgesia regimen. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference23 articles.

1. Obstetric anesthesia workforce survey: Twenty-year update.;Anesthesiology,2005

2. Dose–response relationship of intrathecal morphine for postcesarean analgesia.;Anesthesiology,1999

3. Risks and side-effects of intrathecal morphine combined with spinal anaesthesia: A meta-analysis.;Anaesthesia,2009

4. Mini-dose intrathecal morphine for the relief of post-cesarean section pain: Safety, efficacy, and ventilatory responses to carbon dioxide.;Anesth Analg,1988

5. Ketorolac and spinal morphine for postcesarean analgesia.;Int J Obstet Anesth,1996

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3