Visual assessment of Korotkoff sounds improves the accuracy of a validated professional automated auscultatory blood pressure monitor KOROT P3 Accurate

Author:

Menti Ariadni,Ntineri Angeliki,Kyriakoulis Konstantinos G.,Theodosiadi Aikaterini,Ntousopoulos Vasileios,Stathopoulou Panagiota,Kollias Anastasios,Stergiou George S.

Abstract

Objective: A novel automated auscultatory upper-arm cuff blood pressure (BP) monitor for office use (KOROT P3 Accurate, previously InBody BPBIO480KV), which displays Korotkoff sound curves for each BP reading was recently developed. This study investigated whether the review of Korotkoff sound curves by healthcare professionals further improves the accuracy of the device by identifying unreliable BP readings. Methods: Three observers assessed independently the morphology of Korotkoff sound curves of BP measurements obtained during an ISO 81060-2:2018 validation study, and classified them as of good, fair, or poor quality (low amplitude or sound intensity, aberrant morphology, background noise, signal artifact, auscultatory gap, irregular rhythm). The observers were blinded to the study BP measurements. Results: Korotkoff sound curves of 255 BP readings obtained in 85 individuals were analyzed (mean age 57.3 ± 15.0 years, 53 men). Of the SBP readings 80.4/12.2/7.4% were classified as good/fair/poor, and DBP 76.9/12.2/10.9%. Inter-observer agreement in detecting poor-quality curves was 84.7/83.1% (systolic/diastolic). Of poor-quality curves, 10.5/60.7% (systolic/diastolic) clustered in the same individuals. The validation criterion 1 [mean test-reference BP difference ≤5 ± 8 (SD) mmHg] was satisfied for readings with good (0.1 ± 4.9/0.3 ± 3.8 mmHg, systolic/diastolic) and fair-quality curves (−0.4 ± 6.4/0.2 ± 5.0), but not for poor-quality ones (2.7 ± 8.8/3.6 ± 8.1). By excluding poor-quality readings (40 of 255), criterion 1 of the validation study was improved (0.2 ± 4.9/0.2 ± 3.9 versus 0.3 ± 5.5/0.6 ± 4.7 mmHg). Conclusion: The visual assessment of Korotkoff sounds generated during automated auscultatory BP measurement by the KOROT P3 Accurate professional monitor identifies unreliable readings and further improves the device accuracy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3