Listening Effort Measured With Pupillometry in Cochlear Implant Users Depends on Sound Level, But Not on the Signal to Noise Ratio When Using the Matrix Test

Author:

Stronks Hendrik Christiaan12,Tops Annemijn Laura1,Quach Kwong Wing1,Briaire Jeroen Johannes1,Frijns Johan Hubertus Maria123

Affiliation:

1. Department of Otorhinolaryngology and Head & Neck surgery, Leiden University Medical Center, Leiden, the Netherlands

2. Leiden Institute for Brain and Cognition, Leiden, the Netherlands

3. Department of Bioelectronics, Delft University of Technology, Delft, the Netherlands.

Abstract

Objectives: We investigated whether listening effort is dependent on task difficulty for cochlear implant (CI) users when using the Matrix speech-in-noise test. To this end, we measured peak pupil dilation (PPD) at a wide range of signal to noise ratios (SNR) by systematically changing the noise level at a constant speech level, and vice versa. Design: A group of mostly elderly CI users performed the Dutch/Flemish Matrix test in quiet and in multitalker babble at different SNRs. SNRs were set relative to the speech-recognition threshold (SRT), namely at SRT, and 5 and 10 dB above SRT (0 dB, +5 dB, and +10 dB re SRT). The latter 2 conditions were obtained by either varying speech level (at a fixed noise level of 60 dBA) or by varying noise level (with a fixed speech level). We compared these PPDs with those of a group of typical hearing (TH) listeners. In addition, listening effort was assessed with subjective ratings on a Likert scale. Results: PPD for the CI group did not significantly depend on SNR, whereas SNR significantly affected PPDs for TH listeners. Subjective effort ratings depended significantly on SNR for both groups. For CI users, PPDs were significantly larger, and effort was rated higher when speech was varied, and noise was fixed for CI users. By contrast, for TH listeners effort ratings were significantly higher and performance scores lower when noise was varied, and speech was fixed. Conclusions: The lack of a significant effect of varying SNR on PPD suggests that the Matrix test may not be a feasible speech test for measuring listening effort with pupillometric measures for CI users. A rating test appeared more promising in this population, corroborating earlier reports that subjective measures may reflect different dimensions of listening effort than pupil dilation. Establishing the SNR by varying speech or noise level can have subtle, but significant effects on measures of listening effort, and these effects can differ between TH listeners and CI users.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3