Alternate Electrode Placements to Facilitate Frontal Electroencephalography Monitoring in Anesthetized and Critically Ill Patients

Author:

Isik Oliver G.1,Chauhan Vikas1,Ahmed Meah T.2,Chang Brian A.1,Cassim Tuan Z.3,Graves Morgan C.1,Rajan Shobana4,Garcia Paul S.1

Affiliation:

1. Department of Anesthesiology, Columbia University Vagelos College of Physicians & Surgeons, New York, NY

2. Medical School, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA

3. Department of Psychology, School of Social and Behavioral Science, University of Utah, Salt Lake City, UT

4. Department of Anesthesiology, Cleveland Clinic, Cleveland, OH

Abstract

Background: Frontal electroencephalography (EEG) monitoring can be useful in guiding the titration of anesthetics, but it is not always feasible to place electrodes in the standard configuration in some circumstances, including during neurosurgery. This study compares 5 alternate configurations of the Masimo Sedline Sensor. Methods: Ten stably sedated patients in the intensive care unit were recruited. Frontal EEG was monitored in the standard configuration (bifrontal upright) and 5 alternate configurations: bifrontal inverse, infraorbital, lateral upright, lateral inverse, and semilateral. Average power spectral densities (PSDs) with 95% CIs in the alternate configurations were compared to PSDs in the standard configuration. Two-one-sided-testing with Wilcoxon signed-rank tests assessed equivalence in the spectral edge frequency (SEF-95), EEG power, and relative delta (0.5 to 3.5 Hz), alpha (8 to 12 Hz), and beta (20 to 30 Hz) power between each alternate and standard configurations. Results: After the removal of unanalyzable tracings, 7 patients were included for analysis in the infraorbital configuration and 9 in all other configurations. In the lateral upright and lateral inverse configurations, PSDs significantly differed from the standard configuration within the 15 to 20 Hz band. The greatest decrease in EEG power was in the lateral inverse configuration (median: −97 dB; IQR: −130, −62 dB). The largest change in frequency distribution of EEG power was in the infraorbital configuration; median SEF-95 change of −1.4 Hz (IQR: −2.8, 0.7 Hz), median relative delta power change of +7.3% (IQR: 1.4%, 7.9%), and median relative alpha power change of −0.6% (IQR: −5.7%, 0.0%). Conclusions: These 5 alternate Sedline electrode configurations are suitable options for monitoring frontal EEG when the standard configuration is not possible.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Alternative sensor montage for Index based EEG monitoring. A systematic review;Journal of Clinical Monitoring and Computing;2024-04-27

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3