Pharyngeal Mucosal Pressure and Perfusion

Author:

Brimacombe Joseph1,Keller Christian2,Pühringer Fritz3

Affiliation:

1. Clinical Professor, Department of Anaesthesia and Intensive Care, University of Queensland, Cairns Base Hospital.

2. Consultant Anaesthetist, Department of Anaesthesia and Intensive Care Medicine, Leopold-Franzens University.

3. Associate Professor, Department of Anaesthesia and Intensive Care Medicine, Leopold-Franzens University.

Abstract

Background Pharyngeal airway devices can exert substantial pressures against the pharyngeal mucosa. The authors assess the relation between pharyngeal mucosal perfusion and directly measured mucosal pressure (MP) in the posterior pharynx using a fiberoptic technique with a modified cuffed oropharyngeal airway (COPA). The authors also measure in vivo intracuff pressure (CP), airway sealing pressure and MP at four locations using an unmodified COPA. Methods Twenty adult patients, American Society of Anesthesiologists status I or II, undergoing general anesthesia were allocated randomly to receive either (1) a COPA with a millimeter microchip sensor fixed on the external cuff surface to record distal posterior pharyngeal MP or (2) a COPA with a fiberoptic scope inserted inside the cuff to record digitized images of the distal posterior pharyngeal mucosa. MP and digitized images were obtained at the same location over an in vivo CP range of 10-160 cm H2O in 10- to 20-cm H2O increments. The digitized images were scored according to blood vessel caliber and mucosal color by two investigators blinded to MP and CP. In an additional 20 matched patients, in vivo CP, airway sealing pressure, and MP was measured at four different cuff locations (corresponding to the anterior, lateral, and posterior pharynx and the distal oropharynx) with increasing cuff volume. Results Blood vessel caliber and mucosal color was normal in all patients when the mean mucosal pressure was 17 cm H2O. Blood vessel caliber was first reduced when the mean mucosal pressure was 34 cm H2O. There was a progressive incremental reduction in blood vessel caliber and mucosal color when the mean mucosal pressure increased from 34 to 80 cm H2O (P < or = 0.05). Complete blood vessel collapse and mucosal paling first occurred with the mean mucosal pressure was 73 cm H2O and was present in 90% of patients when the mean mucosal pressure was 80 cm H2O. Mean MP was always higher in the posterior pharynx compared with the other locations when the cuff volume was 20 ml or greater (P < 0.001). In vivo CP is an excellent predictor of mucosal pressure. Mean (95% confidence interval [CI]) MP in the posterior pharynx was 35 (5-67) and 78 (50-109) cm H2O when the airway sealing pressure was 10 (6-16) and 17 (13-21) cm H2O respectively. Conclusion Pharyngeal mucosal perfusion is reduced progressively in the posterior pharynx when MP is increased from 34 to 80 cm H2O with the COPA. CP provides reliable information about MP and should be less than 120 cm H2O to prevent mucosal ischemia.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference12 articles.

Cited by 83 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3