Rate of Coronary Flow Adaptation in Response to Changes in Heart Rate before and during Anesthesia for Coronary Artery Surgery

Author:

van Wezel Harry B.,Kal Jasper E.,Vergroesen Isabelle,Vroom Margreeth B.,De Graaf Ruud,Dankelman Jenny,Porsius Marjolein,Spaan Jos A. E.

Abstract

Background The rate of adaptation of coronary blood flow in response to stepwise changes in heart rate (HR) has been extensively studied in dogs and goats to improve our understanding of the dynamics of coronary regulation processes and their pathophysiology and to obtain time constants for mathematical modeling of the coronary regulation. However, little is known about the dynamic characteristics of coronary flow adaptation in humans. In patients undergoing coronary artery surgery, we investigated the rate of coronary adaptation in response to stepwise changes in HR, in the awake and anesthetized states. Methods In 11 patients with stable coronary artery disease, arterial blood pressure, right atrial pressure, and coronary sinus blood flow, measured by continuous thermodilution, were calculated per beat. The ratio of beat-averaged arterial blood pressure minus right atrial pressure and coronary sinus blood flow was calculated to obtain an index of coronary resistance. The rate of change of coronary resistance index was quantified by t50, defined as the time required to establish 50% of the total change in coronary resistance index. Responses of coronary resistance index after HR changes, before and after induction of anesthesia, were compared. The anesthesia technique consisted of 100 micrograms.kg-1 fentanyl and 0.1 mg.kg-1 pancuronium bromide in combination with oxygen in air ventilation (FIO2 = 0.5). Results In the awake situation, t50 values of the dilating and constricting responses, induced by an increase and a decrease in HR were 5.0 +/- 2.1 (SD) s (range 2.6-9.0 s) and 5.7 +/- 1.2 s (range 4.1-7.8 s), respectively. During fentanyl/pancuronium anesthesia, the rate of coronary flow adaptation was significantly slower, with t50 values of 10.2 +/- 2.1 s (range 7.7-13.1 s) after an HR step-up and 9.8 +/- 2.1 s (range 6.6-13.2 s) after an HR step-down. Compared to the awake situation, arterial blood pressure was significantly reduced during anesthesia, but coronary vascular resistance remained unchanged. This implies that the steady-state static regulation of coronary blood flow had not changed. Conclusions These preliminary data suggest that, in patients with coronary artery disease, the rate of change in coronary vascular resistance in response to pacing-induced changes in HR is mitigated by fentanyl/pancuronium anesthesia during positive pressure ventilation. A further qualification of our findings in a larger number of patients is warranted.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference61 articles.

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3