Author:
Butterworth John,James Robert L.,Lin Yonggu,Prielipp Richard C.,Hudspeth Allen S.
Abstract
Background
Epsilon-aminocaproic acid (EACA) is commonly infused during cardiac surgery using empiric dosing schemes. The authors developed a pharmacokinetic model for EACA elimination in surgical patients, tested whether adjustments for cardiopulmonary bypass (CPB) would improve the model, and then used the model to develop an EACA dosing schedule that would yield nearly constant EACA blood concentrations.
Methods
Consenting patients undergoing elective coronary artery surgery received one of two loading doses of EACA, 30 mg/kg (group I, n = 7) or 100 mg/kg (group II, n = 6) after CPB, or (group III) a 100 mg/kg loading dose before CPB and a 10 mg x kg(-1) x h(-1) maintenance infusion continued for 4 h during and after CPB (n = 7). Two patients with renal failure received EACA in the manner of group III. Blood concentrations of EACA, measured by high-performance liquid chromatography, were subjected to mixed-effects pharmacokinetic modeling.
Results
The EACA concentration data were best fit by a model with two compartments and corrections for CPB. The elimination rate constant k10 fell from 0.011 before CPB to 0.0006 during CPB, returning to 0.011 after CPB. V1 increased 3.8 l with CPB and remained at that value thereafter. Cl1 varied from 0.08 l/min before CPB to 0.007 l/min during CPB and 0.13 l/min after CPB. Cl2 increased from 0.09 l/min before CPB to 0.14 l/min during and after CPB. Two patients with renal failure demonstrated markedly reduced clearance. Using their model, the authors predict that an EACA loading infusion of 50 mg/kg given over 20 min and a maintenance infusion of 25 mg x kg(-1) x h(-1) would maintain a nearly constant target concentration of 260 microg/ml.
Conclusions
EACA clearance declines and volume of distribution increases during CPB. The authors' model predicts that more stable perioperative EACA concentrations would be obtained with a smaller loading dose (50 mg/kg given over 20 min) and a more rapid maintenance infusion (25 mg x kg(-1) x h(-1)) than are typically employed.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Anesthesiology and Pain Medicine
Cited by
56 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献