Background An appropriate measure of performance is needed to identify anesthetic depth indicators that are promising for use in clinical monitoring. To avoid misleading results, the measure must take into account both desired indicator performance and the nature of available performance data. Ideally, anesthetic depth indicator value should correlate perfectly with anesthetic depth along a lighter-deeper anesthesia continuum. Experimentally, however, a candidate anesthetic depth indicator is judged against a "gold standard" indicator that provides only quantal observations of anesthetic depth. The standard anesthetic depth indicator is the patient's response to a specified stimulus. The resulting observed anesthetic depth scale may consist only of patient "response" versus "no response," or it may have multiple levels. The measurement scales for both the candidate anesthetic depth indicator and observed anesthetic depth are no more than ordinal; that is, only the relative rankings of values on these scales are meaningful. Methods Criteria were established for a measure of anesthetic depth indicator performance and the performance measure that best met these criteria was found. Results The performance measure recommended by the authors is prediction probability PK, a rescaled variant of Kim's dy.x measure of association. This performance measure shows the correlation between anesthetic depth indicator value and observed anesthetic depth, taking into account both desired performance and the limitations of the data. Prediction probability has a value of 1 when the indicator predicts observed anesthetic depth perfectly, and a value of 0.5 when the indicator predicts no better than a 50:50 chance. Prediction probability avoids the shortcomings of other measures. For example, as a nonparametric measure, PK is independent of scale units and does not require knowledge of underlying distributions or efforts to linearize or to otherwise transform scales. Furthermore, PK can be computed for any degree of coarseness or fineness of the scales for anesthetic depth indicator value and observed anesthetic depth; thus, PK fully uses the available data without imposing additional arbitrary constraints, such as the dichotomization of either scale. And finally, PK can be used to perform both grouped- and paired-data statistical comparisons of anesthetic depth indicator performance. Data for comparing depth indicators, however, must be gathered via the same response-to-stimulus test procedure and over the same distribution of anesthetic depths. Conclusions Prediction probability PK is an appropriate measure for evaluating and comparing the performance of anesthetic depth indicators.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference61 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3