The Effect of Electronic Record Keeping and Transesophageal Echocardiography on Task Distribution, Workload, and Vigilance During Cardiac Anesthesia

Author:

Weinger Matthew B.,Herndon Oliver W.,Gaba David M.

Abstract

Background Electronic anesthesia record keeping (EARK) systems increasingly are used in the operating room, but studies have only recently begun to investigate their effect on anesthesia task performance. Teak analysis, workload assessment, and vigilance assessment techniques were used to study senior residents providing anesthesia for coronary artery bypass graft (CABG) procedures. The impact on anesthesia residents' workload of the routine use of transesophageal echocardiography (TEE) also was examined. Methods Before each case, the record keeping system was randomly selected as either electronic (Distek ARKIVE; EARK) or traditional manual recording (MAN). Twenty CABG procedures (10 EARK and 10 MAN) were examined, with observation commencing with anesthetic induction and terminating on initiation of cardiopulmonary bypass. The activities of each resident, divided into 32 task categories (e.g., "laryngoscopy," "observe monitors," etc.), were recorded by a trained observer using a computer. The response latency to a randomly activated alarm light was used as a measure of vigilance ("vigilance latency"). Workload was rated by subject and observer at random 10- to 15-min intervals throughout the case. Data analysis included calculation of workload density (number of tasks/min multiplied by task-specific workload values) and task-links (relationship between sequential tasks). Results The two groups had a similar distribution of tasks before intubation. In only 4 of the 20 cases studied did any manual record keeping occur before intubation. After intubation, the EARK group spent less time record keeping and using the TEE but more time observing the monitors and conversing with the attending physician than the MAN group did. All subjects reported significantly higher workload scores before intubation compared with after intubation. Similarly, vigilance latency was greater before intubation compared with after intubation (57 vs. 31 s; P < 0.001). There were no significant differences between the two record keeping groups in subjective workload scores, workload density, or vigilance latency. During TEE use, vigilance latency was significantly longer, and workload density was greater than during other monitoring or recording tasks. Conclusions This study provides an objective description of the task distribution and workload during the administration of anesthesia for cardiac surgery. Under the conditions of this study. EARK use modestly decreased the time spent record keeping during the postintubation prebypass period. However, there was no effect of EARK either on vigilance or several measures of workload. TEE use was associated with increased workload and possibly decreased vigilance.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference26 articles.

Cited by 118 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Enhancing medication safety during the perioperative period;Handbook of Perioperative and Procedural Patient Safety;2024

2. Systems Anesthesiology;Anesthesiology Clinics;2023-12

3. A Novel Web-Based eMemo for Tertiary Institutions in Developing Nations: From Conceptualization to Implementation;Emerging Results in Computing;2023-11-07

4. Improving patient safety: Did we learn from the story of Jean-Pierre Adams?;Journal of Patient Safety and Risk Management;2023-02-15

5. Prevention of Ischemic Injury in Cardiac Surgery;Perioperative Medicine;2022

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3